Installation manual
10
Regency Gemfi re™ Gas Fireplace
INSTALLATION
MANTEL CLEARANCES
Note:  Ensure the paint that is used on the mantel 
and the facing is "heat resistant" or the 
paint may discolour.
MANTEL LEG CLEARANCES
Combustible mantel leg clearances as per diagram:
4"
4"
A
llowable mantel
leg projection
11-1/2” (292mm)
14” (356mm)
15-3/4” (400mm)
1.5" (38mm)
MANTEL LEG
4”
(102mm) Non-Combustible
Drywall
2
0
12
6
4
810
Top o f
Fireplace
Opening
13" (330mm)
3 ½" (89mm)
Standoff
Metal Stud
(On Edge)
0
14
Non-combustible
Facing
To Floor
1" (25mm)
30” (762mm)
20”
21”
28-1/8”
(724mm)
(51mm)
(102mm)
(152mm)
(203mm)
(254mm)
(305mm)
(356mm)
Due to the extreme heat this fi replace emits, the 
mantel clearances are critical. Combustible mantel 
clearances from top of front facing are shown in the 
diagram on the right.
Note: A non-combustible mantel may be 
installed at a lower height if the framing 
is made of metal studs covered with a 
non-combustible board.