Manual Owners & Installation LISTINGS AND CODE APPROVALS These gas appliances have been tested in accordance with AS4553, NZS 5262 and have been certified by the Australian Gas Association for installation and operation as described in these Installation and Operating Instructions. Your unit should be serviced annually by an authorised service person.
REGENCY GAS INBUILT FIREPLACE TO THE NEW OWNER Congratulations! You are the owner of a state-of-the-art Gas Inbuilt Fireplace by FPI. The Regency Gas Fireplace Series of appliances has been designed to provide you with all the warmth and charm of a fireplace, at the flick of a switch. The model IG34 of this series has been approved by Australian Gas Association for both safety and efficiency.
TABLE OF CONTENTS DATA BADGE Copy of Data Badge .....................................................4 INSTALLATION Important Message ........................................................5 For Your Safety ..............................................................5 Before You Start ............................................................5 Installation Checklist ......................................................5 Materials Required ........................................................
DATA BADGE This is a copy of the label that accompanies each Regency IG34 Gas Inbuilt fireplace. We have printed a copy of the contents here for your review. Check the label on the unit and if there is a difference, the label on the unit is the correct one. DATA BADGE NOTE: Regency units are constantly being improved. Regency Gas Fireplace Distributed by: Model Gas Type Model NG LPG ULPG IG34-NG IG34-LPG IG34-ULPG Gas Consumption 31.7mj. 30.6mj. 26.4mj. Manifold Pressure 0.87 kPa 2.
INSTALLATION IMPORTANT MESSAGE BEFORE YOU START The Regency Gas Inbuilt must be installed in accordance with these instructions. Carefully read all the instructions in this manual first. Installation is to be carried out ONLY by an authorised person. Note: Failure to follow these instructions could cause a malfunction of the heater which could result in death, serious bodily injury, and/or property damage. Failure to follow these instructions may also void your fire insurance and/or warranty.
INSTALLATION MINIMUM FIREPLACE DIMENSIONS Mantel Clearances FLUEING THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE AND MUST BE TERMINATED TO THE OUTDOORS. The minimum fireplace dimensions for the Regency gas space heater are shown in the following diagrams: This appliance is designed to be attached to two 3" (76mm) co-linear aluminium flex running the full length of the chimney. The flue length must be a minimum length of 8 ' (2.
INSTALLATION The Air Intake pipe must be attached to the inlet air collar of the termination cap. 4) Seal and or check the pilot outlet (# 8) 5) The pressure check should be carried out with the unit burning and the setting should be within the limits specified on the safety label. 6) When finished reading manometer, turn off the gas valve, disconnect the hose and tighten the screw (clockwise) with a 1/8" flat screwdriver. Screw should be snug, but do not over tighten.
INSTALLATION INSTALLATION IN MASONRY OR ZERO CLEARANCE CHIMNEY 1) Measure and record dimensions to determine total Flex Liner length requirements (see instructions below for details). 2) Carefully feed the liner down the chimney (masonry or zero clearance) and out through the damper. One person should feed the liner through the chimney, and another person should pull the liner from the bottom.
INSTALLATION System Data IG34 IG34-NG: For 0 to 610 meters altitude IG34-LPG: For 0 to 610 meters altitude IG34-ULPG: For 0 to 610 meters altitude Burner Inlet Orifice Sizes: NG LPG Burner #37 #52 Max. Input NG LPG ULPG 31.7 mj 30.6 mj 26.4 mj Min. Input NG LPG ULPG 21.1 mj 25.1 mj 20.9 mj Supply Pressure NG LPG ULPG 1.13 kPa 2.75 kPa 2.75 kPa Manifold Pressure HIGH NG 0.87 kPa LPG 2.51 kPa ULPG 2.51 kPa ULPG #53 LOW 0.4kPa 1.6kPa 1.6kPa Electrical: 240 V. 50Hz.
INSTALLATION Conversion Kit #486-968 for NG to LPG Model THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Conversion Kit 486-968 Contains: Qty. Part # 1 904-345 1 918-273 1 918-272 1 910-037 1 918-823 Description Burner Orifice #51 Red "LPG" label Label "Converted to LPG" LPG Pilot Injector Instruction Sheet 1) Shut off the gas supply and unplug the power cord. 2) Remove the glass door, logs and lava rock.
INSTALLATION 18) Turn on gas supply and plug in power cord. 19) Adjusting the Outlet Pressure After carrying out all adjustments, block the setting screws with paint, taking care not to obstruct the breather orifice of the pressure. Put back the modulator plastic cap. All the adjustments must be carried out in the following order: Remove the modulator plastic cap (A) using needle nose pliers.
INSTALLATION Conversion Kit #486-967 for NG to ULPG THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Conversion Kit 486-967 Contains: Qty. Part # 1 904-345 1 918-273 1 918-272 1 910-037 1 918-824 Description Burner Orifice #53 Red "ULPG" label Label "Converted to ULPG" LPG Pilot Injector Instruction Sheet 1) Shut off the gas supply and unplug the power cord. 2) Remove the glass door, logs and lava rock.
INSTALLATION 18) Turn on gas supply and plug in power cord. 19) Adjusting the Outlet Pressure All the adjustments must be carried out in the following order: After carrying out all adjustments, block the setting screws with paint, taking care not to obstruct the breather orifice of the pressure. Put back the modulator plastic cap. Remove the modulator plastic cap (A) using needle nose pliers.
INSTALLATION OPTIONAL STAINLESS STEEL INNER PANEL INSTALL Before you start: Stainless panels must be inspected for scratches and dimples prior to installation. All claims to be recorded at this time. Claims for damage after installation will not receive consideration. To protect the finish during installation and handling - cotton gloves MUST be worn at all times while handling the panels (even when removing protective coating). Stainless panels will discolor a little during normal operation.
INSTALLATION LOG SET INSTALLATION Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation.
INSTALLATION 5) Place the Middle Left Log C)02-56 on the two pins as shown. 7) Place the notch in Center Log E)02-47 over Log B)0245 and across the cutout on Log A)02-43. E)02-47 A)02-43 C)02-56 B)02-45 Notch Cutout Logs A)02-43, C)02-56, and B)02-45 in position Logs D)02-46 and E)02-47 in position. 6) Place the Left Top Log D)02-46 on the pin on Log C)02-56 and on top of the cutout on Log A)02-43.
INSTALLATION Front edge of rear burner 10) Place the embers and Rockwool on the exposed front burner tray. A)02-43 B)02-45 F)02-48 Side View Bracket The bottom right edge of Log F)02-48 must sit snugly against the bracket and the front edge of the rear burner. 11) Separate platinum embers and place on and around the embers and rockwool on the burner tray. Avoid stacking platinum embers. 9) Place Front Left Log G)02-44 onto the 2 front pins as shown.
INSTALLATION GLASS DOOR INSTALLATION STANDARD FLUSH DOOR The standard flush door comes with a black frame. To install the frame and glass door, simply hook the top door flange onto the top of the unit and swing the door towards the unit, diagram 1. Be careful that the glass gasket does not roll up; there must be a gap between the gasket and the door lip to ensure that the door sits securely on the unit. See Diagram 2.
INSTALLATION FACEPLATE & OPTIONAL PLINTH TRIM ASSEMBLY 1) Lay the faceplate panels flat, face down on something soft so they don't scratch. 2) Take the top faceplate and align the holes in it with the holes in the side panels. Secure with provided nuts and bolts.
INSTALLATION FACEPLATE AND DOOR FRAME INSTALLATION 1) Position faceplate on unit lining up screw holes on faceplate with screw holes on unit - secure with 4 screws. 4) Push both bottom frame hinges down on the metal lip until they are fully seated. 5) Flip bottom louver up to close. 2) Install lower screw below glass door - secure with 4 screws. Note: Ensure that the flanges on the sides of the firebox are on the outside, when installing the faceplate (see below).
INSTALLATION THERMODISC INSTALLATION 1) Install faceplate and door frame as per previous page. 5) Secure wiring along the vertical right side of the faceplate (facing the back of the faceplate) with supplied grey adhesive clips. 2) After faceplate has been installed - place the touch pad (facing out) in the knockout located on the left side of the faceplate. 3) Secure with 2 screws as shown below. Back of Faceplate 6) Slide unit into final position.
INSTALLATION FINAL CHECK Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly. This includes: 1) Clocking the appliance to ensure the correct firing rate (rate noted on label) at 15 minutes. 2) If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for 15 min. to stabilize. 3) Check for proper draft.
OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS Before operating this appliance, proceed through the following check list. 1) Read and understand these Instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no gas leaks. 4) Make sure the glass door is in place. Never operate the appliance with the door glass removed. 5) Verify that all flueing and the cap is unobstructed. 6) Verify log placement.
OPERATING INSTRUCTIONS COPY OF LIGHTING INSTRUCTION PLATE FOR YOUR SAFETY READ BEFORE LIGHTING This appliance must be installed in accordance with local codes, if any; if not, follow the current CAN1-B149/ANSI Z 223.1 (Australia: AS5601-2004, New Zealand: NZS 5261) WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
MAINTENANCE MAINTENANCE INSTRUCTIONS Any maintenance required accessing the glass door of the unit must be performed by an authorized service person. 1) Always unplug the power cord before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleaning the logs, use a soft clean brush as the logs are fragile and easily damaged.
MAINTENANCE FAN MAINTENANCE To Remove Fan: 1) Turn the unit off and allow it to cool to room temperature, 2) Unplug or disconnect power source to stove. 3) Open the bottom louvre. 4) Remove screws that secure protective screen. 5) Remove door frame and screen 6) Remove the ECS harness from the back clip. 7) Pull out the ECS box. NOTE: The ECS box is held in place with velcro. 8) Remove the 2 screws that secure the fan in place.
MAINTENANCE VALVE ASSEMBLY REPLACEMENT 1) Unplug or disconnect the power source to the stove and shut off gas supply. 2) open bottom louvre and remove protective screen. 3) Remove the door frame and safety screen. 4) Remove the glass door, logs, and black or stainless inner liner, if installed. 5) Remove the rear log tray, burner and grate. 6) Disconnect gas line from the valve. 7) Remove the firebox base plate by removing the 10 screws which hold it in place.
PARTS LIST ELECTRONIC COMPONENTS PARTS LIST 910-936 910-082 910-089 910-088 910-912 910-084 910-527 910-935 910-080 910-906 910-521, 910-522, 910-523, 910-525 FG37 FG38 FG39 PG33 PG36 HG35 PG36D 910-083 910-514 910-916 PG121/PG131 IG35 IG34 910-909 Fan Resistor 910-936 Intermittent Pilot N/A N/A 910-082 Direct Spark Ignitor N/A N/A N/A N/A N/A N/A N/A 910-089 Flame Cable N/A N/A N/A N/A N/A N/A N/A 910-088 Spark Cable N/A N/A N/A N/A N/A N/A N/A N/A N/A 910-084 Co
PARTS LIST MAIN ASSEMBLY Part # Description 1) 910-169/P Fan Motor (240 V)** 2) 910-995 Thermodisc** 3) 486-968 486-967 LPG Conversion Kit** ULPG Conversion Kit** 4) Valve Assembly - NG Valve Assembly - LPG SIGMA Valve 845 Part # 10) 910-936 910-947 Pilot Assy (NG) - 3 flame convertible top Pilot Assy (LPG) - 3 flame convertible top 11) 904-240 904-645 Orifice #37 (NG) Orifice #51 (LP) 12) 336-013 13) 936-155 14) 940-307/P 5) 336-574/P 336-576/P 910-080 6) 336-001 Valve Tray Gasket** 7)
PARTS LIST FACEPLATE ASSEMBLY Part # Description 14) 336-914 Faceplate & Trim Complete - Regular 15) 366-942 Plinth Kit 16) 336-532 Flush Screen Door** *Not available as a replacement part.
WARRANTY Regency® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. Regency® is pleased to extend this limited lifetime warranty to the original purchaser of a Regency® Product.
FIREPLACE PRODUCTS AUSTRALIA PTY. LTD. 21-23 SOUTH LINK, DANDENONG SOUTH VICTORIA, 3175 AUSTRALIA © Copyright 2009, FPI Fireplace Products International Ltd. All rights reserved.