Manual Owners & Installation LISTINGS AND CODE APPROVALS These gas appliances have been tested in accordance with AG 103, NZS 5262 and have been certified by the Australian Gas Association for installation and operation as described in these Installation and Operating Instructions. Your unit should be serviced annually by an authorised service person.
To the New Owner: Congratulations! You are the owner of a state-of-the-art Masport Room Sealed Gas Fire by FPI Fireplace Products International Ltd. The Masport Gas Series of hand crafted appliances has been designed to provide you with all the warmth and charm of a woodstove, at the flick of a switch. The models F39-NG, and F39-LPG of this series has been approved by AGA for both safety and efficiency.
TABLE OF CONTENTS Page Safety Label Safety Labels ................................................................... 4 Installation Important Message .......................................................... 5 Specifications ................................................................... 5 Before You Start ................................................................ 5 General Safety Information ............................................... 5 Installation Checklist .............................
SAFETY LABEL This is a copy of the label that accompanies each MASPORT F39 Room Sealed Freestanding Gas Stove. We have printed a copy of the contents here for your review. The data plat is located on the inside of the drop down pedestal door. NOTE: Masport units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
INSTALLATION IMPORTANT: SAVE THESE INSTRUCTIONS The MASPORT Room Sealed Freestanding Gas Fire must be installed in accordance AG601 and NZS 5261 and with these instructions. Carefully read all the instructions in this manual first. Consult the building authority having jurisdiction to determine the need for a permit prior to starting the installation. Note: Failure to follow the instructions could cause a malfunction of the heater which could result in death, serious bodily injury, and/or property damage.
INSTALLATION 10) Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination. 11) Under no circumstances should this appliance be modified. Parts that have to be removed for servicing should be replaced prior to operating this appliance. 12) Installation and any repairs to this appliance should be done by an authorised service person. An authorised service person should be called to inspect this appliance annually.
INSTALLATION LOUVRE INSTALLATION 1) Attach the top & bottom louvres to the side stove panel using 2 screws per side. FLUEING INTRODUCTION INSTALLATION PRECAUTIONS The DV Fire Horizontal Flue Kit and the Simpson Dura-Flue Room Sealed System Model DV-GS fluing systems, in combination with the Masport Room Sealed Freestanding Gas Fire, F39-NG, and F39-LPG, have been tested and listed as direct flue heater systems by AGA.
INSTALLATION EXTERIOR FLUE TERMINATION LOCATIONS Minimum clearances required for balanced flue terminals or the flue terminals of outdoor appliances according to AG 601 (AGA gas installation code) or NZS 5261 (New Zealand) For vertical termination heights refer to AG 601 or NZS 5261.
INSTALLATION FLUEING ARRANGEMENTS Horizontal Terminations for All Flueing Systems The shaded areas in the diagram below show all allowable combinations of vertical runs with horizontal terminations. Maximum one 90O elbow (two 45o elbows equal one 90o elbow). LPG and NG: Residential, Manufactured and Mobile Homes Installations The fluing arrangements shown below, have a min. of 75% (flue loss) efficiency with Fan Off, as required for manufactured homes.
INSTALLATION GAS CONNECTION PRESSURE TESTING The gas connection is a 3/8" NPT 90o elbow. The gas line can be rigid pipe or to make installation easier, use a listed flexible connector and/or copper tubing if allowed by local codes. Since some municipalities have additional local codes it is always best to consult with your local authorities. The manifold pressure is controlled by a regulator built into the gas control, and should be checked at the pressure test point.
INSTALLATION AERATION ADJUSTMENT System Data F39 with 40mj Burner Inlet Orifice Sizes: NG Burner #32 2.95mm LPG #50 1.78mm Max. Input NG LPG 40 Mj/h 38 Mj/h Min. Input NG LPG 20 Mj/h 19 Mj/h Supply Pressure NG min. 1.13 kPa LPG min. 2.75 kPa Manifold Pressure NG .94 kPa LPG 2.55kPa The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude.
INSTALLATION CONVERSION FROM NG TO LPG THIS CONVERSION MUST BE DONE BY AN AUTHORIZED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Conversion Kit #730-969 Contains: Qty. Part # 1 910-018 1 1 1 1 1 910-037 904-641 908-528 908-255 918-032 Description SIT Conversion Kit50% Turndown LPG LPG Injector (Pilot Orifice) Burner Orifice #50 Red "LPG" label Label "Converted to LPG" Instruction Sheet 7) Unscrew the pilot orifice with the allen key and replace with the LPG pilot orifice in the kit.
INSTALLATION LOG SET INSTALLATION CONVERSION TO LOWER BTU RATING THIS CONVERSION MUST BE DONE BY AN AUTHORIZED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! NG Conversion Kit 730-920 Contains: Qty. Part # Description 1 904-240 Burner Orifice #37 (NG) 1 918-034 Decal "Converted to 30,000 Btu" 1 918-033 Instruction Sheet LPG Conversion Kit 730-922 Contains: Qty.
INSTALLATION 3) Place Rear Log A)02-65 on the two pins on the rear log support. 7) Place the Left Top Log D)02-46 on the pin on Log B)02-56 and on top of the cutout on Log A)02-65. 11) Position notch in Front Right Log G)02-48 on Log F)02-47 and push the bottom right edge against the bracket on the burner tray. G)02-48 A)02-65 A)02-65 A)02-65 -47 D)02-46 E)02-45 F)02 B)02-56 C)02-44 Pins on Rear Log Support 4) Place the Middle Left Log B)02-56 on the two pins as shown.
INSTALLATION FRONT DOOR INSTALLATION (packaged separately) 1) Open the two side panels. 2) Slide the door onto the two hinge pins making sure the two pieces are flush together. See diagram 1. OPTIONAL WALL THERMOSTAT OPTIONAL REMOTE CONTROL A wall thermostat may be installed if desired. Connect the wires as per the wiring diagrams. Note that the wires are connected to the "TH" on the gas valve.
INSTALLATION WIRING This heater does not require a 240V A.C. supply for the gas control to operate. A 240V A.C. power supply is needed for the fan/blower operation. Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. NOTE: Switch must be in "OFF" position to operate remote.
OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS Before operating this appliance, proceed through the following check list. 1) Read and understand these Instructions before operating this appliance. SHUTDOWN INSTRUCTIONS 1) Turn OFF the flame switch. 2) Push in gas control knob slightly and turn to "OFF" position. FIRST FIRE 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no gas leaks.
OPERATING INSTRUCTIONS COPY OF THE LIGHTING PLATE INSTRUCTIONS NORMAL OPERATING SOUNDS OF GAS APPLIANCES FOR YOUR SAFETY READ BEFORE LIGHTING This appliance must be installed in accordance with local codes, if any; if not, follow the current CAN1-B149/ANSI Z 223.1 (Australia: AG601, New Zealand: NZS 5261) WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
MAINTENANCE MAINTENANCE INSTRUCTIONS 1) Always turn off the valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleaning the logs, use a soft clean paint brush as the logs are fragile and easily damaged. 2) Clean glass (never when unit is hot), appliance, louvres, and door with a damp cloth. Never use an abrasive cleaner.
MAINTENANCE LOG REPLACEMENT The unit should never be used with broken logs. Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs. The pilot light generates enough heat to burn someone. If for any reason a log should need replacement, you must use the proper replacement log. The position of these logs must be as shown in the diagram under Log Installation.
MAINTENANCE 7) Tighten side panels nuts using the following procedure: a. tighten top & bottom outside corner nuts (2) b. tighten inside nuts (3) c. tighten top & bottom inside corners (2) 8) Tighten the 10 nuts on center glass retainer. 9) Repeat step 7 for other side panel. To Remove F39 Fan: 1) Unplug or disconnect power source to stove. 2) Remove all logs and the rear log support, then remove the 10 screws holding the access panel in place. 3) Unclip the black and white wires from the fan motor.
MAINTENANCE REMOVING VALVE If your valve requires maintenance or replacement, use the following instructions: Note: Always close off the gas supply before removing the valve. 4) Remove the two outside frame pieces by removing two screws per side. See diagram below. 9) Carefully lift the burner tray assembly out. 10) To replace the burner tray assembly, simply reverse these instructions. 1) Open front pedestal door.
PARTS LIST F39 MAIN ASSEMBLY Part#: Aust.
PARTS LIST F39 BURNER & LOG ASSEMBLY Part#: Aust. New Zealand 54) 55) 56) 57) 910-373 910-372 918-088 * Description 588412 Knob - Pilot Valve Extension 588413 Flame Adjusting Knob Control Plate Decal Switch Plate 730-574/P 60) 910-378 588394 904-688 556172 936-170 556174 910-074 Valve Assembly - NG Valve - S.I.T. - NG #32 Orifice - N.G. Orifice Gasket Spark Generator Switch c/w Wire 66) 910-038 910-039 Pilot Assy - S.I.T. - 3 Flame NG Pilot Assy - S.I.T.
PARTS LIST F39 DOOR ASSEMBLIES Part#: Aust. New Zealand 101) 105) 106) 107) 108) 111) 112) 208) Description 730-924 Gold Mitred Door - Complete 730-926 Black Mitred Door - Complete 730-932 Gold Wrap Door - Complete 730-928 Gold Panel Door - Complete 650-920 560018 Door Gasket Kit * Ceramic Paper 940-323/P Side Glass 936-243 560087 Glass Gasket 940-322/P Centre Glass * Door Frame Fibre Paper 750-015 Door Glass Extrusion 940-325/P Wrap Glass *Not available as a replacement part.
NOTES _____________________________________________________________________________________ ____________________________________________________________ __________________________________________________________ ____________________________________________________________ _______________________________________________________ _____________________________________________________ __________________________________________________________ _________________________________________________________ ___________
WARRANTY THE MASPORT EXPRESS WARRANTY All new Masport Gas appliances are warranted, subject to the following conditions, to be free from defects in material or workmanship under normal use. The Express Warranty on all parts, including firebox components is two years from date of original purchase as well as labour costs involved in the repair or replacement.
© Copyright 2004, FPI Fireplace Products International Ltd. All rights reserved.