13
INSTALLATION
FRAMING
Framing Dimensions Description B41XTCE
M Framing Width 47-1/4"(1200mm)
N Framing Height 49-1/2" (1257mm)
O (Rear Vent) Framing Depth - Rear Vent 26-1/2" (673mm)
O (Top Vent) Framing Depth - Top Vent 25-7/8" (657mm)
P Corner Facing Wall Width 65-1/4" (1657mm)
Q Corner Facing Wall Width 91-11/16" (2329mm)
R (Rear Vent) Framed Chase Ceiling - Rear 49-1/2" (1257mm)
R (Top Vent) Framed Chase Ceiling - Top 54-1/2" (1384mm)
S (Rear Vent) Vent Centerline Height - Rear 28-1/2" (724mm)
S (Top Vent) Vent Centerline Height - Top 47-1/2" (1207mm) Rigid / Flex
T Gas Connection Height 1-1/2" (38mm)
U Gas Connection Inset 5" (127mm)
V Gas Connection Width 3-1/4" (82mm)
W Non-Combustible Top Height 13-1/2" (343mm)
** Important: Framing height requires consideration of the hearth depth. Dimension N = N + the thickness of the installed hearth.
M
N
O
Q
P
R
U
V
T
Opening for gas
connection
11" (279mm)
dia. Hole through
wall Vent.
Non-Combustible
Header
(steel stud) on edge
Drywall
(or other
facing)
W
Non-Combustible Facing
S
S
Non-Combustible
Header
(steel stud)