Instruction Manual

10
Regency Bellavista™ B41XTCE Gas Fireplace
INSTALLATION
Caution Requirements
The top, back and sides of the replace are de ned by
standoffs. The metal ends of the standoff may NOT be
recessed into combustible construction.
WARNING
Fire hazard is an extreme risk
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this replace and vent
system be installed only in accordance with these instructions.
CLEARANCES
The clearances listed below are Minimum distances unless otherwise stated:
A major cause of chimney related res is failure to maintain required clearances (air space) to combustible materials. It is of the greatest
importance that this replace and vent system be installed only in accordance with these instructions.
B41XTCE Clearance Requirements
Horizontal Top 3" (76mm)
Horizontal Side 2 " (51mm)
Horizontal Bottom 2" (51mm)
Vertical Vent 2" (51mm)
NOTE: A 16" deep non-combustible hearth pad is
recommended for hardwood ooring and carpet.
Clearance: Dimension Measured From:
A: Mantel Height (min.) 17-9/16" (446mm) Top of Fireplace Opening
B: Sidewall 9" (229mm) Side of Fireplace Opening
C: Ceiling 36-5/8" (930mm) Top of Fireplace Opening
D: Mantel Depth (max.) 12" (304mm) 25-13/16" (651mm)
from Top of Fireplace Opening
E: Alcove Width 60" (1524mm) Wall to Wall (Minimum)
F: Alcove Depth 36" (914mm) Front to Back Wall (Maximum)
Notes: 0" No Hearth Required
Minimum Vent Clearances
to Combustibles
Alcove
E
F
C
D
A
E
F
C
Close to Ceiling
F
E