- FPI Fireplace Products Gas Log Fireplace Owners & Installation

Regency
®
P36-4 Gas Log Fireplace 15
INSTALLATION
FLUEING ARRANGEMENTS - VERTICAL TERMINATIONS
SIMPSON DURA-VENT CO AXIAL FLUE GS SYSTEM (LPG & NG)
The P36 is approved for a 23 ft. (7.0m) vertical, with a maximum 12 ft. (3.7m) horizontal offset
using two 90
o
elbows (two 45
o
elbows equal one 90
o
elbow) with Simpson Dura-Vent Co Axial
Flue GS ue systems for LPG and NG, as per diagram 1.
The P36 is approved for a 37 ft. (11.3m) straight vertical, including a 20" (0.5m) horizontal offset
using two 90
o
elbow (two 45
o
elbows equal one 90
o
elbow) with Simpson Dura-Vent Co Axial
Flue GS ue systems for LPG and NG, as per the diagram 2.
Flue must be supported at offsets
Maintain clearances to combustibles as listed in section "Clearances."
Note: Must use optional ue adapter when using Simpson Dura-Vent pipe
(Part # 510-994).
Note: Regency
®
Co Axial Flue System (Flex) is only approved for horizontal
terminations.
Diagram 1
Diagram 2