Installation Instructions

Recommended Products:
Reflective/Bubble/Bubble/White - Roll: RDBW48100 (48”x 100’)
Open Interior with 1”x 2” Furring
R-7.5* Heat Flow Down
R-3.6* Heat Flow Up
Installation Instructions:
The Reflectix
®
Insulation is installed with the “white side” towards the interior of the building.
Pre-installation inspection - Check the roof area for clutter, water sprinklers, conduit and lights.
Sprinkler systems are especially important. All water pipes must be below the Reflectix
®
Reflective/Bubble/Bubble/White Insulation to prevent the possibility of freezing in the winter. In
many instances the Reflectix
®
product must be installed up near the roof deck.
Install 1”x 2” furring strips on the bottom of and perpendicular to the Z purlins on 22” centers.
Utilize 1 1/4” self-tapping sheet metal screws to secure the furring strips to the Z purlins.
Butt the furring strips together and tape. Staple tape for reinforcement.
Attach the product using 5/16” staples at approximately 4” intervals.
Staple the edges of the Reflectix
®
Reflective/Bubble/Bubble/White product to the furring strips with a
3/4” overlap at the seams.
1. Reflectix
®
Insulation
2. Exterior Roof Panel
3. Purlin
4. 1”x 2” (Nominal)
Furring Strip
5. Red Metal (Structural
Frame)
Tools Required:
Safety Glasses
Tape Measure
Utility Knife
Screw Gun
Staple Gun
Metal Building / Roof / Retrofit
Reflectix Installation Instructions
2
1
3
5
4