Installation Instructions
Recommended Products:
Reflective/Bubble/Bubble/White - Roll: RDBW48100 (48”x 100’)
Inside the Girts
Open Interior • R-4.2* Heat Flow Horizontal
Installation Instructions:
• The Reflectix
®
Insulation is installed with the “white side” towards the interior of the building.
• Reflectix
®
Reflective/Bubble/Bubble/White Insulation can be installed either vertically or
horizontally.
• Attach the product to the inside of the girts using 5/16” staples at approximately 4” intervals.
• Tape the seams with a Reflectix
®
White Poly Tape (goal is an air-tight, snug seam seal).
* Includes thermal resistance of 0.68 interior air film.
Calculation Disclaimer: All values are calculated based on the “ASHRAE Handbook of Fundamentals”.
1. Reflectix
®
Insulation
2. Exterior Wall Panel
3. Girt
4. Post
Tools Required:
Safety Glasses
Tape Measure
Utility Knife
Staple Gun
Post Frame Building / Wall / Retrofit
Reflectix Installation Instructions
2
1
3
4