Pro Residential, Post Frame and Metal Building Applications
Recommended Products:
Staple Tab, Reflective/Bubble/Bubble/Reflective - Roll: ST48100 (48”x 100’)
Inside the Girts
Metal Interior • R-6.3 Heat Flow Horizontal
Open Interior • R-5.3* Heat Flow Horizontal
Installation Instructions:
• The Reflectix
®
Reflective/Bubble/Bubble/Reflective, Staple Tab product can be installed either
vertically or horizontally.
• Attach the product to the inside of the girts using 5/16” staples at approximately 4” intervals.
• Tape the seams with a Reflectix
®
Foil Tape (goal is an air-tight, snug seam seal).
• For interior covering, attach 1”x 2” furring strips perpendicular to the girts through the insulation.
• Attach interior panel to the furring strips.
• This will provide a 1” (nominal) air space between the interior panel and the insulation and a 1 1/2”
air space between the insulation and the outside panel.
1. Reflectix
®
Insulation
2. Exterior Wall Panel
3. Girt
4. Post
Tools Required:
Safety Glasses
Tape Measure
Utility Knife
Staple Gun
Post Frame Building / Wall / Retrofit
Reflectix
®
Installation Instructions
2
1
34