Installation Guide
N24 LowesCan Revised 0915
TESTING & CERTIFICATIONS
• Thermal Performance ASTM C518
• Fungus Resistance Mil-Std 810B Method 508
• Pliability Test ASTM C1224
• Water Vapor Transmission ASTM E96
• Tensile Strength ASTM D751
MANUFACTURER’S SUGGESTED INSTALLATION INSTRUCTIONS
Note: Installation instructions and illustrated drawings are recommendations only,
while proper local construction methods are the responsibility of the installer.
RADIANT FLOOR OVER AN EXISTING FLOOR
• Unroll the Reflectix
®
Concrete Slab Insulation over the existing floor prior to pouring the concrete (white poly side facing up). Cut product flush with
the walls.
• Butt the seams of the product and seal with 3” wide poly tape. Note: Utilize a flat edge taping tool to assure good adhesion on all tape.
• Install Radiant Floor System per manufacturer’s specifications.
RADIANT FLOOR IN A CONCRETE SLAB
• Unroll the Reflectix
®
Concrete Slab Insulation product over the base material prior to pouring the concrete (white poly side facing up).
• Butt the seams of the product and seal with 3” wide poly tape. Note: Utilize a flat edge taping tool to assure good adhesion on all tape.
• Install Radiant Floor System per manufacturer’s specifications.
CONCRETE SLAB (SNOW MELT)
• Unroll the Reflectix
®
Concrete Slab Insulation product over the base material prior to pouring the concrete (white poly side facing up).
• Butt the seams of the product and seal with 3” wide poly tape. Note: Utilize a flat edge taping tool to assure good adhesion on all tape.
• Install Snow Melt System per manufacturer’s specifications.