Federal Communications Commission (FCC) Statement • • • • English English This Equipment has been tested and found to comply with the limits for a class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Table of Contens 4 7 11 12 13 14 17 18 20 20 23 23 23 24 24 23 27 29 30 30 42 45 English Getting Started Quick Installation Guide (QIG) Installing Software and Driver Installing Hardware Loading 120 Films into the Holder Loading 120 Film Holder into the Scanner Loading 135 Film into the Holder Loading 135 Mounted Slides into the Holder Loading 135 Film and Slide Holder into Scanner How to Scan STEP 1 - Powering On the Scanner STEP 2 - Select Film Type STEP 3 - Optional Prescan STEP 4 - Set Sc
Getting Started Check the package content before getting started. For Quick Installation please refer to Quick Installation Guide. (Pg. 11) English Important! Save the original box, receipt and packing material for future shipping needs or to return for warranty issues. Package Contents • Scanner unit. • Medium format film holder for one or two frames (6 x 4.5 cm, 6 x 6 cm), one frame (6 x 7 cm, 6 x 8 cm, 6 x 9 cm, 6 x 12 cm). • 135 film holder. • 135 slide holder.
Operating Ambient Temperature Range 50º to 104ºF (10º to 40ºC) English Note: Do not turn on the scanner unless it is within this range. If the scanner has been stored or transported outside of this range, allow it to return to within this range before turning it on. Operating Ambient Humidity Range 15% to 76% relative humidity (non-condensing) Note: If the scanner is stored or to be transported in cold temperature and then brought into a warm / humid environment condensation may occur.
Quick installation guide (QIG) English Scanner - front view Power button Scan button Opening for 135 film & slide holder Opening for 120 film LED light Scanner - rear view USB 2.
INSTALLING SOFTWARE AND DRIVER INSTALLING SOFTWARE AND DRIVER WINDOWS SYSTEMS INSTALLATION: DURING DRIVER INSTALLATION A WARNING DIALOGUE BOX MAY APPEAR, IF THIS IS THE CASE PLEASE SELECT “INSTALL THIS DRIVER ANYWAY”. Before Installing the scanner driver... Be sure to install the Application Software (ex: Adobe® Photoshop® Elements) BEFORE installing the CyberView X scanner driver software.
Loading 120 film into the holder Loading 120 film into the holder (continued) 120 film holder Tabs Lock Tab Tab English English Upper latch Closed lower latch Lettering Triangle mark (photo positioning indicator) Lower latch (with photo size ruler) 1. As illustrated above, turn the holder with the embossed lettering “120 FILM HOLDER” facing towards the top, so that the letters “abc” and the numbers on the lower latch are oriented as indicated.
Loading 120 film into the holder (continued) 4. To flatten the film close the upper latch and adjust it by shifting it up and down. English English Shift up and down ex.: correctly positioned film, lower left corner at the triangle mark 5. OPTIONAL: Lock the film in the holder by moving the lock bar to the left. The silver fastener will be next to the closed lock icon embossed on the bar. Position: unlocked ex.
Loading 135 film into the holder English cb a 135 film holder a. Orient film strip based on the example graphic “abc” on the holder. cba Dividers English cba Loading 135 film into the holder (continued) Horizontal guides b. Open the film holder by pulling down on the tab from the bottom center of the holder. Lift the front part of the holder. The top side of the holder is marked with white arrows. c. lnsert the orientated film negative into the holder between the horizontal guides.
Loading 135 mounted slides into the holder 135 slide holder English cba cba a. Orient slides based on the example graphic “abc” on the holder. b. Insert mounted slides into the holder. O INCORRECT P CORRECT Loading 135 film and slide holder into the scanner Place the film holder into the scanner from the left or right side into the small opening. Make sure that the orientation of white arrows on the holder correspond with the triangle mark on the scanner (see previous page for illustration).
HOW TO SCAN STEP 1 – Powering on the scanner Scanner Status Unit will take approx. 40-50 sec. to callibrate. The power LED will be solid green (not blinking) to indicate that the scanner is ready to use. Status LED - On solid Ready state. Film holders can be inserted/removed Blinks (on/off change) Scanner is busy, do not turn the unit off. Insert/remove film holders. Flashes several times, then a pause, then flashes again Scanner is malfunctioning. Turn the unit off, close the software. After approx.
STEP 3 – Optional Prescan Pre-Scanning should be used to manually adjust color/edit settings before doing a final scan. In the CyberView interface click on the “Prescan” menu bar icon. The scanner will initialize the prescanning process. 2. Once the prescan is complete, the image will appear in the CyberView interface: 3. When the image appears on the screen, select the “Final scan icon“ to scan the file into a folder on the hard drive. STEP 4 – Set Scan Settings 1.
STEP 6 – Exit For details on scanning resolution and file sizes: All scaned images will be saved to the directory location set previously. The factory default locations are: Default Scanning Resolution Color Depth Film Size Approx. File Size* 1000dpi 8-bit 35mm 3.93 MB 1000dpi 8-bit 6 x 4.5 11.97 MB 1000dpi 8-bit 6x6 15.96 MB 1000dpi 8-bit 6x7 18.63 MB 1000dpi 8-bit 6x9 23.94 MB 1000dpi 8-bit 6 x 12 31.92 MB 1000dpi 16-bit 35mm 7.87 MB 1000dpi 16-bit 6 x 4.5 23.
USER INTERFACE English 28 29
There are three major parts of the CyberView X user interface: Color adjustment features. English English I. Menu Commands [Overview + Full] II. Function Bar Diagram / Toolbar Diagram III. Active Frame Settings Area Menu Commands - Image Adjustment (overview) I. Menu Commands [Overview] Menu Commands - Window (overview) Menu Commands - Scan (overview) Settings for the CyberView window and Exposure adjustment for the scanner. a. Prescan b. Scan c.
Menu Commands [Full] Menu Commands - Scan (full) Prescan the existing film. b. Scan 1. Scan Selected to File… > Scan the selected film to a specified path. 2. Enter the file name. 2-1. Trailing Index after Base File Name Digits: Defines the length of the file name and numbering sequence up to 6 digits Example image1 or image000001. • Options: • Use Film Index: Use the number assigned to the film frame. • User Defined Start Number: Enter a specific start number. • 1-1.
2. Advanced Setting English English Allows for automatic settings via the Cyberview software for Exposure, Balance and Contrast. With these items checked the software will perform automatic adjustments. When unchecked, no color correction etc. will be performed leaving the adjustment up to the user in the post scan/editing process in an image editing application software. 2-1. ”Auto Exposure” - Apply Auto Exposure adjustment to all of the scanned films. 2-2.
Menu Commands - Preview 2. Color Balance To adjust the brightness, contrast, saturation, and color (CMY or RGB) of the image. Comparisons between before and after adjusted images are shown for reference. English English 1. Un/Lock scanning area. 2. Zoom In: Magnify image. 3. Zoom Out: Reduce image. 4. Rotate 90 Left: Turn the image 90° counter clockwise. 5. Rotate 90 Right: Turn the image 90° clockwise. 6. Flip Horizontal: Flip the image horizontally. 7. Flip Vertical: Flip the image vertically. a.
3. Curves and Levels Exposure Setting: To adjust the exposure time (R, G, B) press ”Reset” to restore to the default setting. English English Adjust image settings by moving Curve and Levels settings. Comparison between before and after adjustment is displayed for reference. Menu Commands - Windows Menu Commands - Help User Manual: Opens the electronic version of this user’s manual. Update Firmware: Upgrade the firmware version, select the path where the file of firmware has been saved.
English Preview Window In order to optimize scanned image quality, please select your film type and brand from the toolbar: Negative Positive (also known as Slide) Black and White Preview the pre-scan image by selecting the measurement unit „in“- inches, „cm“- centimeters, „px“ - pixels by clicking the upper-left corner. English II. Function Bar Diagram Prescan: Pre-scan the current film. Scan: Scan film. Image Adjustment: Press drop down button for more options.
III. Active Frame Setting Area A comprehensive advanced mode is available to allow for more user defined adjustments. English Normal mode [ex: I] to input the basic parameter to scan (including scan resolution, film size, color depth). Advanced mode [ex: II]to input the parameter of scan and output (including scan resolution, size, color depth and output resolution, size, scan mode).
TECHNICAL SUPPORT CyberView X English For information regarding the film scanner and CyberView X driver, please visit www.reflecta.de. Bundled application software For questions regarding bundled application software, you can refer to the HELP function on the application menu bar or visit the software company’s website. **This user manual has also been archived in the packaged CD.