English User’s Manual 1
Federal Communications Commission (FCC) Statement English This Equipment has been tested and found to comply with the limits for a class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
Table of Contens 4 English Getting Started Quick Installation Guide (QIG) Installing Software and Driver Installing Hardware Loading the slides into the Magazine Loading the Magazine into the Scanner Additional Features One Button Scan How to Scan Slides STEP 1 - Aquire Driver STEP 2- Select Film Type STEP 3 - Optional Prescan STEP 4 - Set Scan Settings STEP 5 - Scan STEP 6 - Exit User Interface I Main Window Area II Preview Window Area III Active Frame Setting Area IV Thumbnail Panel Area Technical Supp
Getting Started Check the package content before getting started. For Quick Installation please refer to Quick Installation Guide. (Ref. Pg. 11) English Important! Save the original box, receipt and packing material for future shipping needs. Package Contents • Slide Scanner. • Magazine. • Power Adapter [HIGH POWER HPA-401234U3 or LINEARITY LAD6019AB4] Warning! Using any other power adapter may severely damage the scanner and will void the product warranty. • Power Cord. • USB 2.0 Cable.
Operating Ambient Temperature Range 50º to 104ºF (10º to 40ºC) English Note: Do not turn on the scanner unless it is within this range. If the scanner has been stored or transported outside of this range, allow it to return to within this range before turning it on. Operating Ambient Humidity Range 15% to 76% relative humidity (non-condensing) Note: If the scanner is stored or to be transported in cold temperature and then brought into a warm / humid environment condensation may occur.
Quick Installation Guide (QIG) INSTALLING SOFTWARE AND DRIVER English for PC (Windows) User WINDOWS SYSTEMS INSTALLATION DURING DRIVER INSTALLATION A WARNING DIALOGUE BOX MAY APPEAR, IF THIS IS THE CASE PLEASE SELECT “INSTALL THIS DRIVER ANYWAYS”. Be sure to install the Application Software BEFORE installing the scanner driver CyberView X 5.0. You may install the scanner driver directly if you have already installed TWAIN compliant application software in your computer.
INSTALLING SOFTWARE AND DRIVER for Mac (OSX) User Before Installing the Scanner Driver... English Installing Scanner Driver a. Insert insert driver CD into the computer CD/DVD drive and explore the contents. b. Double click the ”CyberView X 5.0” icon to begin the installation process. Follow the onscreen prompts to complete the installation process. NOTE: Make sure the scanner is NOT connected to the computer during the CyberView X 5.0 driver installation. c.
Loading slide(s) into the magazine Loading slide(s) into the magazine CS Magazine Universal Magazine English English a. Locate the numbering sequence text on the top of the Universal slide magazine indicating the slide order. The numbers should be facing up and starting from the left. b. Hold the slide right side up, facing forward so the image is NOT reversed. Rotate the slide as illustrated below (180 deg) and Insert each slide, one at a time, into the magazine. a.
Load the magazine into the scanner (Continued) Compact Magazine NOTE: • Use only Universal Magazines with the DIN 108 label. Other magazines may result in problems and VOIDing the warranty. English English (embossed letters facing up and the white stripe near the front panel of the scanner). Universal Magazine • Pull out the slide transport arm fully. • Gently press the orange adapter on the slide transport arm. Move the adapter on the slide transport arm to the front until it snaps in.
Additional features English Manual Control Panel Please Note: When installing your new scanner onto a Windows system that already has another USB Flatbed scanner or All-in-one Scan/Copier/Printer device installed, it may be necessary for you to disconnect the other scanner from the USB port for the Film scanner to work properly, One Button Scan Open the CyberView X 5.0 driver program FIRST and press the scan button to scan the film or slide. a. Open the CyberView X 5.0. (Ref.
d. Single Slide Scanning • Load the empty magazine into the tunnel FIRST until it touches the English slide transport arm completely. Slide the magazine forward to be sure that the transport arm is in the first slot of the magazine. • Press the eject button [I] to make the slide holder open exposing the loaded slide. • Place the slide as illustrated [I] into the slide holder and press the slide holder down [II]. • Open the CyberView X 5.0 driver program to scan the slide.
HOW TO SCAN SLIDES STEP 1 – Acquire Driver English (For PC User) Open CyberView X 5.0 from Start – All Programs –CyberView X 5.0 (For MAC User) Open Macintosh Hard drive – Applications –CyberView X 5.0_MS –CyberView X 5.0 STEP 2 – Select Film Type Select the film type to be scanned - Positive, Negative or B&W (Black and White). STEP 3 – Optional Prescan Select the “Prescan Current Frame“ to prescan the slide currently loaded into the scanner or “Prescan...
STEP 5 – Scan STEP 4 – Set Scan Settings Choose “Scan Current Frame” to scan the slide loaded into the scanner or “Multi-Scan…” to input the number of slides to be scanned based on their location in the magazine. English English a. Resolution The default scanning resolution is 1000dpi, additional resolution options are listed below. Notice: Higher scanning resolutions result in greater scanning time and hardisk space requirements. b. Color Depth Choose between 8 and 16bit.
STEP 6 – Exit All scaned images will be saved to the directory location set previously, The factory default locations are: English Windows: C:\Users\[YOUR NAME\Documents; MAC: Mac HD\Users\[YOUR NAME]\Pictures\Cyberview Images), Select “Scan > Exit” to close the driver. Scanned image files can be open/ edited with any image editing software.
USER INTERFACE English 28 29
There are four major parts of theCyberView X 5.0 user interface: b. Scan English English I. Main Window Area [Fixed Windows] II. Preview Window Area [Fixed Window] III. Active Frame Setting Area [Floating Window] IV. Thumbnail Panel Area [Floating Window] I. Main Window Area [Fixed Windows] 1. Scan Current Frame > Scan the current slide. 2. Scan Selected to File… > Scan the selected slide(s) to a specified path. 3. Multi-Scan to File… > Scan slide(s) numbers and/or range.
3-3. Trailing Index after Base File Name 1. Scan Settings • Digits: Defines the length of the file name and numbering sequence up to 6 digits Example image1 or image000001. • Options: • Use Film Index: Use the number assigned to the slide based on it’s position in the cartridge. User Defined Start Number: Enter a specific start number. 3-4. Choose the file type , “TIF” or “JPG”. (TIF uncompressed or JPG Compressed) 1-2. “Using default real scan resolution“ - Enables default scan resolution setting.
2. Advanced Setting 2-1. ”Auto Exposure” - Apply Auto Exposure adjustment to all of the scanned films. English 2-3. “Auto Contrast” - Apply Auto Contrast adjustment to all of the scanned films. Closes theCyberView X 5.0 user interface. There is a message pop-up “Would you like to apply current scan resolution to default?“ click “Yes“ to save , “No“ to discard the current setting or “Cancel“ to return to Cyber View X. English 2-2. ”Auto Balance” - Apply Auto Gamma adjustment to all of the scanned films.
Menu Commands - Preview 2. Color Balance To adjust the brightness, contrast, saturation, and color (CMY or RGB) of the image. Comparisons between before and after adjusted images are shown for reference. English English 1. Zoom In: Magnify image. 2. Zoom Out: Reduce image. 3. Rotate 90 Left: Turn the image 90° counter clockwise. 4. Rotate 90 Right: Turn the image 90° clockwise. 5. Flip Horizontal: Flip the image horizontally. 6. Flip Vertical:Flip the image vertically. a. Image Adjustment 1.
3. Curves and Levels 1. Exposure Setting: To adjust the exposure time (R, G, B) press ”Reset” to restore to the default setting. English English Adjust image settings by moving Curve and Levels settings. Comparison between before and after adjustment is displayed for reference. Menu Commands - Windows Menu Commands - Help • User Manual: Opens the electronic version of this user’s manual. • Update: Firmware: Upgrade the firmware version, select the path where the file of firmware has been saved.
Function Bar Diagram ROC: Automatically restores original colors by analyzing the base image and applying corrections to the faded colors. (ONLY AVAILABLE ON OLDER UNITS WITH BUILT IN DIGITAL ICE3™ TECHNOLOGY.) GEM: Automatically enhances the clarity of a scanned film image while preserving its colors, gradations and sharpness. (ONLY AVAILABLE ON OLDER UNITS WITH BUILT IN DIGITAL ICE3™ TECHNOLOGY.
III. Active Frame Setting Area [Floating Windows] A comprehensive advanced mode is available to allow for more user defined adjustments. English Images only appear here in Prescan mode, scan to file goes directly to the hard drive, this window remains blank as does the main Cyberview X 5.0 window. English Normal mode [ex: I] to input the basic parameter to scan (including scan resolution, film size, color depth).
TECHNICAL SUPPORT CyberView X 5.0 English For information regarding the film scanner and CyberView X 5.0 driver, please visit www.reflecta.de. Bundled application software For questions regarding bundled application software, you can refer to the HELP function on the application menu bar or visit the software company’s website. **This user manual has also been archived in the packaged CD.