Technical data
148
Technical informations f
or
REFCO Vacuumpumps
Technische
Hinweise
für
REFCO
Vakuumpumpen
Important
Prior to the
first useo
fREFCO vacuum
pumps please
check if the
voltage and cycles indicated
on the
data shield
is compatible with the
tension
and cycles of your electricity board.
If not specified
in your
order, we supply all
our pumps for 220 volts and
50 hertz.
For transport reasons the
pump
does not contain
any oil when
i t is
shipped.
Before the
first use the
pump
must bef
illed with the
oil
provided.
If condensable
g as is being
evacuated, the
pump must run
on work-
ing temperature(
approx. 5minutes)
and gas ballast valve
must be
opened.
Never use
REFCO vacuum
pumps as a
compressor
.
Maintenance
Please note: the
most impor
tant ser
vice factor is the
oil. The oil
must be
changed
at least every 20 hours of ser
vice. Dirty oil or oil
which is contaminated with
moisture
or acid g az will damage the
vacuum pump.
The REFCO vacuum
pump will
keep its capacity as long
as the oil is
clean and the c orrect type
is used.
The correct type
is: C-10 or of
course all the oils which
are supplied
by REFCO sucha
s: DV-04,
DV-05, DV-06 and
DV-08,
as well
as Esteroil
Type P-15-S.
Warranty
During the
1 year warranty period, the vacuum
pumps must not be
opened
or disassembled
by any other than
REFCO.P
lease note, that
REFCO will refusea
ll claims if the
pump has been
opened
prior to
REFCO’
s inspection.
Cleaning
of vacuum pump
If the original vacuum
capacity cannot be reached
anymore ( after
warranty period), the
pump can be disassembled
and the
parts can
be cleaned withp
arafin.
If necessary also
change the rotary vanes.
When reassembling
also change
all the gaskets.R
EFCO
is offering
gasket sets for all
REFCO vacuump
umps.
Cold star
tof vacuum
pump
REFCO vacuum
pumps start easily at an
ambient temperature
of
+8° centigrade
a nd higher
.The pump reaches top speed wi
thin
30 seconds.
The maximum
end vacuum
is reached
after approxima-
tely 5 minutes.
The pump will
not run as indicated
above,
if other oils than
C-10 or
REFCO oils are
being used.
During the
cold season the
pump must be transported
in the drivers
compartment of the
car and
not in the
boot. The temperatures in the
boot could
be below the required
cold start minimum
of +8° centi-
grade.
Evacuation
of R134a (HFC)-systems
For the
evacuation
of aR134a-system
are no different vacuum
mp
s r
eq
uired since the
vacuum
pump i s regarded
as a tool
for
p
r
o
c
e
ss
and does therefore
not make
part of the
fe
ty r
e
a
sons it is v
ery important to use
0
.1
33
m
bar.Onall R134a-
mo
u
n
t
is
Wichtig
Vor der Erstinbetriebnahme
m uss die
Stromart und
Netzspannung
überprüft werden.
Falls bei
der Bestellung
nicht anders angegeben,
werden
die Pumpen
immer für 220 V
olt und
50 Hertz geliefert.
Aus Transportgründen werden
die Pumpen
immer ohne
Öl geliefert.
Dieses muss vor Erstgebrauche
ingefüllt werden.
Das richtige
Öl liegt
der Pumpe
bei.
Kondensierbare
Dämpfe
nur bei betriebswarmer Pumpe und
geöffnetem
Gasballastventil
absaugen.
Die Pumpe
darf nicht als Kompressor eingesetzt werden.
Wartung
Der wichtigsteW
artungsfaktor aller V
akuumpumpen
ist das Öl.
Dieses muss nach
höchstens 20 Betrieb
sstunden
gewechselt
werden.
Verschmutztes Öl
kann die Pumpe
beschädigen.
Ein
Ölwechsel
muss auch
nach jedem
Einsatz vorgenommen werden,
wenn verschmutztes Kältemittel
evakuier
t wurde.
Damit die
REFCO
Vakuumpumpen
ihre Leistung
behalten,
darf nur
C-10 Öl oder die von
REFCO
gelieferten
Öle (DV-04, DV-05, DV-06,
DV-08 oder Esteröl
P-15-S)
verwendet werden.
Garantie
Während
der 12-monatigen
Garantiezeit
darf die Pumpe
nur durch
REFCO geöffnet oder demontiert werden.
Das Öffnen
oder Demon-
tieren der Pumpe
durch
andere Stellen
als REFCO
hat den
Verlust
jeglicher Garantieansprüche zur Folge.
Reinigung
der Pumpe
Eine Demontage und
Reinigung
der Pumpe
(nachAblauf der Garan-
tiezeit) wird
nötig,
falls trotz Ölwechsels nicht mehr die ursprüngliche
Leistung
erreicht wird.
In diesem
Fall können
die Einzelteile
mit
Paraffin
gereinigt werden.
Bei der Montage
der Pumpe sollen
auch
sämtliche
Dichtungen
ersetzt werden.
REFCO
b ietet für sämtliche
REFCO
Pumpentypen
den entsprechenden
Dichtungssatz an.
Kaltstartder Pumpe
Alle REFCO-Pumpen
laufen problemlos bis zu einer Umgebungs-
temperatur von
+8° Celsius problemlos an.
Ca. 30 Sekunden
nach
dem Start läuft der Motor auf
der Maximaldrehzahl.
Nach einer
Laufzeit von
ca.5Minuten wird
die Betriebstemperatur sowie
das
garantierte
Endvakuum
erreicht.
Bitte beachten
Sie, dass während
der kalten
Jahreszeit die
Pumpe
im beheizten
Te il eines Fahrzeugs
transportiert wird.
Die Te mperatur im
Kofferraum
oder im Laderaum
kann unter der Minimaltemperatur von
+8° liegen, was ein
Anlaufen
der Pumpe verunmöglicht.
Absaugen von
R 134a (FKW)-Anlagen
Grunds
ätzlich braucht es für R134a-Anla
gen keine anderen Vakuum-
pumpen,
da die Pumpe
ja ein Werkzeug zum
Evakuieren
des Kälte-
systems darstellt und
daher nicht Bestandteil
des Kältekreislaufes ist.
Aus Sicherheitsgründen, respektive zum
Erreichen
eines genügend
hohen Endvakuums, sollen solche
R134a-Systeme
immer mit einer
2-stufigen
Vak uumpumpe
evakuiert werden.
Ein Endvakuum von
100 micron
= 0.133 mbar ist zwingend,d
adie Esteröle stärker hygro-
skopisch sind.
Da
s Esteröl
der R134a-Anlage
darf unter keinen
Umständen
mit dem
mp
u
mpenöl
in Verbindung
kommen.
Während
des normalen
s
i
st
die
s unmöglich.
Vakuumpumpenöl
kann
us
f
a
ll
n
ac
hgezogenem
Vakuum
meiden
h
a
t
REFCO
Üb
General
The following
c onditions apply if
no other written verifications have
been agreed upon.
All specifications,
datas and
pictures of the
men-
tioned
articles are subject to
c hange without notice.
Prices
The prices are subject to
change
and understood
ex works net,
e xclu-
ding packing,
insurance,
VATand any other taxes.
Order confirmation
Orders will
be confirmed
in writing.
This confirmation
is compulsery for the
acceptance
of
any orders.
Variations of
q uantities
Variations of
±10 % to the
ordered quantity is accepted
for customers‘ specific
executions.
Delivery times
All indicated
delivery times will
be maintained wherever possible,
but are subject to
change.
In no case the customer may withdraw an
order or claim
a ny additional
costs.
Partial deliveries
Partial
deliveries
are accepted
and are regardeda
s an individual
con-
tract.
Transport risk
After the
goods are
despatched, the
customer is responsible
for any
risk regarding the
goods.
Right of
possession
All supplied
goods remain
in ownership
of REFCO until
full payment
b
een
m
a
de.
d
ys
ne
t
a
fter date
oi
ed.
I
f
t
he
Grundlagen
Für alle Lieferu ngen gelten
die nachgenannten
Bedingungen, sofer
n
nicht schriftlich
abweichende
Vereinbarunge
n getroffen wer
den. Alle
Beschreibungen,D
aten und
Abbildungen
der aufgeführ
ten Artikel
sind unverbindlich.
Änderungen
der Konstr
uktion und
Ausführung
bleiben vor
behalten.
Preise
DiePreise verstehen sich
freibleibend
ab Werk,ausschliess-
lich Verpackung,V
ersicherung,M
ehrwertsteuer und sonstige
Gebühren.
Auftragsbestätigung
Die Annahme von
Aufträgen wird schriftlich
b estätigt.
Erst mit der
Auftragsbestätigung
gelten
die Aufträge
als angenommen.
Mengentoleranz
Bei Sonderanfertigungen sind
Abweichungen von
der bestellten
Menge bis zu ± 1 0% zulässig.
Liefer
fristen
Die angegebenen
Lieferfristen werden
nach M öglichkeit eingehalten,
sind aber unverbindlich.
Bei allfälliger Überschreitung
der Fristen
ist
der Besteller nicht berechtigt,
den Auftrag zu annullieren
oder Scha-
denersatzansprüche zu stellen.
Teillieferungen
Te illieferungen sind zulässig und
gelten jeweils als selbständiges
Geschäft.
Nutzen und
G efahr
Gehen grundsätzlich
mit dem
V ersand,
d.h. sobald
die Ware das
Werk verlassen
hat, an den Käufer über
.
Eigentumsvorbehalt
Die gelieferte
Ware bleibt bis zur vollständ
igen Bezahlung
Eigentum
von REFCO.
Zahlungsbedingungen
Die Zahlung
hat innert 30 T
agen nach Fakturadatumn
etto
ohne irgendwelche
Abzüge zu erfolgen.
D
ie
Za
hlungen
für Teillieferungen
haben gemäss Rechnungsstellung
Za
hl
u
ng
s
f
rist werden
die handelsüblichen
Ver-
b
eh
a
l
t
en.
Terms and
conditi
ons of
sale
Verkaufs- und
Lieferbedingungen
150
166
Numerical
Index
Nummernverzeichnis
SFR
Designation
Page
Part No
Unit Price
Bezeichnung
Seite
Best.-Nr
.S
tückpreis
SFR
Designation
Page
Part No
Unit Price
Bezeichnung
Seite
B est.-Nr.S
tückpreis
RFA-206-FB-01
9
4
9881625
10.00
RFA-209 1
03
9881649
20.00
RFA-274-FC
94
9881630
34.00
RFA-274-FC-01
9
4
9881624
10.00
RFA-312-FB
94
9881629
40.00
RFA-312-FB-01
9
4
9881623
10.00
RFA-364-FHB-04
102
9881670
68.00
RFA-364-FHB-051
02
9881669
68.00
RFA-364-FHB-06
102
9881668
94.00
RFA-364-FHB-08
102
9881667
110.00
RFA-364-FHB-101
02
9881666
178.00
RFA-364-FHB-121
02
9881665
220.00
RFA-368-FH
102
9881657
70.00
77
9881008
10.00
77
9881010
75.00
9881
00
9
105.00
7
4
0
.
00
SPP-5
129
9881401
28.00
SPP-6
129
9881400
42.00
SPP-220
129
9881402
25.00
SS-100
113
9881704
21.00
ST-220
129
9881403
12.00
ST2-3-M-R12
48
9885039
155.00
ST2-3-DS-R12
48
9883764
155.00
ST2-3-M-R134a
48
9883765
155.00
ST2-3-DS-R134a
48
9883766
155.00
ST2-6-M-R12
48
9885038
130.00
ST2-6-DS-R12
48
9882653
130.00
ST2-6-M-R134a4
8
9883762
130.00
ST2-6-DS-R134a4
8
98837
63
130.00
ST2-8-M-R12
48
9885037
95.00
ST2-8-DS-R12
48
9883598
95.00
ST2-8-M-R134a
48
9883487
95.00
ST2-8-DS-R134a
48
9882658
95.00
ST
AR
-
2
-3-M-R12
51
9885027
180.00
DS
R
1
2
51
9883778
180.00
51
9883779
180.00
988
37
8
0
180.00
REFCO Manufacturing Ltd.
Industriestrasse 11
CH-6285 Hitzkirch (Switzerland)
10
153
Technische Daten
Verkaufsbedingungen
Artikelverzeichnis
Technical Data
Sales Conditions
Numerical Index
Telefon +4141919 72 82
Telefax +4141919 72 83
info@refco.ch www.refco.ch