R7100 Photo-Contact Tachometer Instruction Manual REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.
Table of Contents Introduction.................................................................................................... 3 Product Quality............................................................................................... 3 Safety............................................................................................................. 3 Features.......................................................................................................... 3 Specifications.................
Introduction Thank you for purchasing your REED R7100 Photo-Contact Tachometer. Please read the following instructions carefully before using your instrument. By following the steps outlined in this manual your meter will provide years of reliable service. Product Quality This product has been manufactured in an ISO9001 facility and has been calibrated during the manufacturing process to meet stated product specifications.
Specifications RPM Range (Contact): RPM Range (Photo): Surface Speed Range: Resolution: Basic Accuracy: General Specifications Visible Indicator: Target Distance: Response Time: Sampling Time: Display Size/Type: Auto Shut-off: Internal Memory: Laser Class: Low Battery Indicator: Power Supply: Product Certifications: Operating Temperature: Storage Temperature: Operating Humidity: Dimensions: Weight: 0.5 to 19,999 2.5 to 99,999 0.05 to 1,999.9 m/min Photo: 0.1 RPM (≤999.9)/1 RPM (>1000) Contact: 0.
Included • • • • • • • Reflective Tape Large and Small Cone Tip Adapters Funnel Adapter Wheel Adapter Batteries Mounting Screws Hard Carrying Case Instrument Description 1. Surface Wheel Adapter 2. Shaft Extension with Large Cone Adapter 3. Contact Adapter 4. Laser Sensor (for non-contact measurement) 5. Measure Button 6. Function Switch 7. Memory Recall Button 8. LCD Display 2 3 4 5 6 7 8 REED Instruments 5 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.
Operating Instructions Applying Reflective Marking Tape 1. 2. 3. 4. 5. Cut and peel the adhesive tape provided into approximately 0.5" (12mm) squares. Apply one square to each rotation shaft. The non-reflective area must always be greater than the reflective area. If the shaft is normally reflective, it must be covered with black tape or black paint before attaching reflective tape. The shaft surface must be clean and smooth before applying the reflective tape. Photo Measurements 1. 2. 3.
Surface Speed Measurements 1. 2. 3. 4. Slide the function switch to the "m/min contact" position. Install the surface wheel adapter on the instrument. Press the Measure button while lightly pressing the surface wheel against the surface being measured. Release the Measure button when the display reading stabilizes (approx. 2 seconds). NOTE: If the inside part of the wheel is used (as shown in the picture), measurements are required to be multiplied by 0.9 for an accurate measurement.
To display these values, follow the steps below: 1. Press and hold the MEM button once. A value is displayed followed by the "UP" symbol, which represents the maximum value. 2. Release the MEM button. 3. Press and hold the MEM button again. A second value is displayed followed by the "dn" symbol, which represents the minimum value. 4. Release the MEM button. 5. Press and hold the MEM button again. A third value is displayed followed by the "LA" symbol, which represents the last value. 6.
Accessing Stored Measurements The meter has the capability of storing up to 64 values during a single measuring period. In order to recall these values, follow the steps below: 1. Press the MEM button four times and hold it down. 2. The meter will begin to countdown from 20 to 1 RPM indicating it is compiling the stored values. 3. Once the countdown is completed, a total of the values stored will display as "An XX", whereas XX will be the number of stored measurements. 4.
Applications • Identify issues with rotational equipment such as: Conveyors, Turbines, Compressors, Fans and Blowers. • Automated Assembly and Production Lines Product Care To keep your instrument in good working order we recommend the following: • Store your product in a clean, dry place. • Change the battery as needed. • If your instrument isn’t being used for a period of one month or longer please remove the battery. • Clean your product and accessories with biodegradable cleaner.
Product Disposal and Recycling Please follow local laws and regulations when disposing or recycling your instrument. Your product contains electronic components and must be disposed of separately from standard waste products. Product Support If you have any questions on your product, please contact your authorized REED distributor or REED Instruments Customer Service by phone at 1-877-849-2127 or by email at info@reedinstruments.com. Please visit www.REEDInstruments.
TEST & MEASURE WITH CONFIDENCE CHECK OUT OUR LATEST PRODUCTS! REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.