R6001 ThermoHygrometer Instruction Manual REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.
Table of Contents Introduction................................................................................................. 2 Product Quality............................................................................................ 3 Safety.......................................................................................................... 3 Features....................................................................................................... 3 Specifications.............................
Product Quality This product has been manufactured in an ISO9001 facility and has been calibrated during the manufacturing process to meet stated product specifications. If a certificate of calibration is required please contact the nearest authorized REED distributor or authorized Service Center. Please note an additional fee for this service will apply. Safety Never attempt to repair or modify your instrument.
Min: Max: Relative Function: Sampling Rate: Auto Shut-off: Low Battery Indicator: Power Supply: Product Certifications: Operating Temperature: Storage Temperature: Operating Humidity Range: Dimensions: Weight: Yes Yes Yes 2.5 times/sec. Yes (30 mins/off) Yes 9V battery CE -4 to 140°F (-20 to 60°C) 14 to 140°F (-10 to 60°C) 10 to 80% 9.5 x 2.1 x 1.3" (240 x 54 x 34mm) 6.4oz (180g) Included • Carrying Case • Battery Instrument Description 1. 2. 3. 4. 5. 6. 7. 8.
Display Description Relative Indicator Data Hold Indicator Minimum Indicator Maximum Indicator Low Battery Indicator Humidity Measurement Unit Indicator Auto Power Off Indicator Temperature Display Operating Instructions Indication de la fonction de Indication du mode de relativisation Press the ON/OFF button to turn the meter ON or OFF.
MAX/MIN Function Press the MAX/MIN button to access Maximum and Minimum modes. When pressing the MAX/MIN button once, the MAX Indicator will appear on the display. The maximum temperature and maximum humidity values are displayed and will automatically update when new maximum data values are measured. 3. Press the MAX/MIN button again and the MIN indicator appears on the display.
2. 3. 4. 5. When the LCD flashes, press the REL button to enter calibration mode. This will be indicated by "CAL 1" on the LCD. Insert the tip of the meter into the 33%RH Humidity Calibration Standard (REED R9933) and press the MAX/MIN button once the reading has stabilized which may take up to 10 minutes. The calibration adjustment will be confirmed by a long beep. The meter will then display "CAL 2" to calibrate the second calibration point (75%).
Accessories and Replacement Parts CA-05A Soft Carrying Case R9933 33% Humidity Calibration Standard R9975 75% Humidity Calibration Standard R9980 33% and 75% Humidity Calibration Kit Don't see your part listed here? For a complete list of all accessories and replacement parts visit your product page on www.reedinstruments.com.
Product Warranty REED Instruments guarantees this instrument to be free of defects in material or workmanship for a period of one (1) year from date of shipment. During the warranty period, REED Instruments will repair or replace, at no charge, products or parts of a product that proves to be defective because of improper material or workmanship, under normal use and maintenance. REED Instruments total liability is limited to repair or replacement of the product.