R5500 Circuit Breaker Finder/ Receptacle Tester Instruction Manual www.REEDINSTRUMENTS.com REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.
Table of Contents Introduction.................................................................................................... 2 Product Quality............................................................................................... 2 Safety............................................................................................................. 3 Warning................................................................................................... 3 Features...............................
Safety Never attempt to repair or modify your instrument. Dismantling your product, other than for the purpose of replacing batteries, may cause damage that will not be covered under the manufacturer's warranty. Servicing should only be provided by an authorized service center. Warning When this symbol appears, refer to the Operating Instructions to avoid misuse. This could lead to injury or damage of the instrument. This symbol indicates that this instrument offers double insulation protection.
Specifications Voltage Range: Bandwidth: Power Supply: Product Certifications: Operating Temperature: Operating Humidity: Storage Temperature: Dimensions: Weight: 90 to 120V AC 47 to 63Hz 1 x 9V ETL 32 to 104°F (0 to 40°C) 0 to 85% -4 to 140°F (-20 to 60°C) 4.1 x 2.2 x 1.2" (103 x 56 x 30mm) 3.9oz (110g) Instrument Description Circuit Breaker Finder 1. LED Indicator Light 2. Sensitivity Adjustment Wheel 3. Battery Compartment Transmitter 4. GFCI Test Button 5. Indicator Lights Reference Guide 6.
Operating Instructions Always test on a known good circuit prior to using the meter. Refer all indicated problems to a qualified electrician. Note: All appliances or equipment on the circuit under test should be unplugged in order to avoid erroneous readings. This instrument will not: • Indicate quality of ground. • Detect 2 hot wires in circuit. • Detect a combination of defects. • Indicate reversal of grounded and grounding conductors.
4. At the breaker box, while set at the highest sensitivity, orient the receiver as per the diagram to scan the surface of the circuit breaker panel. Move the receiver from top to bottom on each side of the breaker panel. NOTE: Failure to orient the receiver as depicted may result in faulty readings. 5. While moving the receiver, gradually reduce the sensitivity to pinpoint the exact breaker/fuse associated to the circuit under test. Receptacle Wiring Test 1. 2.
GFCI Socket Tester 1. 2. 3. 4. Prior to using the transmitter, press the TEST button on the installed GFCI receptacle. This will cause the GFCI to trip. If it trips, press the RESET button on the receptacle. If it does not trip, do not use the circuit and call a qualified electrician. Plug the transmitter into the socket, check that the circuit is connected correctly according to the LED indicators. Press the GFCI button for at least 8 seconds, the indicator lights will turn off when the GFCI trips.
Product Care To keep your instrument in good working order we recommend the following: • Store your product in a clean, dry place. • Change the battery as needed. • If your instrument isn't being used for a period of one month or longer please remove the battery. • Clean your product and accessories with biodegradable cleaner. Do not spray the cleaner directly on the instrument. Use on external parts only.
Product Support If you have any questions on your product, please contact your authorized REED distributor or REED Instruments Customer Service by phone at 1-877-849-2127 or by email at info@reedinstruments.com. Please visit www.REEDINSTRUMENTS.com for the most up-to-date manuals, datasheets, product guides and software. Product specifications subject to change without notice. All rights reserved.