Full Product Manual

Table Of Contents
6
Accuracy
Notes:
Measurement performed at the test socket.
Measurements performed after correct open and short calibration.
DUT and test leads must be properly shielded.
Q value is the reciprocal of DF.
Accuracies based within 10% to 100% of full scale of range; values
outside of range should be used as reference only.
"---" means parallel or series measurement mode.
Inductance @ Ta = 18 to 28°C (De)
Frequency = 100 Hz/120 Hz
Range Resolution Lx Accuracy DF Accuracy
Measurement Mode
20.000mH 1µH 1.5% ±10d 1.5% ±50d Series
200.00mH 0.01mH 1.4% ±15d 1.4% ±50d Series
2000.0mH 0.1mH 1.5% ±15d 1.5% ±50d Series
20.000H 1mH 1.6% ±10d 1.6% ±50d ---
200.00H 0.01H 1.3% ±10d 1.3% ±50d Parallel
2000.0H 0.1H 2.0% ±15d 2.0% ±50d Parallel
20.000kH 0.001kH 2.5% ±15d 2.5% ±50d Parallel
Frequency = 1kHz
Range Resolution Lx Accuracy DF Accuracy Measurement Mode
2000.0µH 0.1µH 1.3% ±10d 1.3% ±50d Series
20.000mH 1µH 1.2% ±10d 1.2% ±50d Series
200.00mH 0.01mH 1.2% ±10d 1.2% ±50d Series
2000.0mH 0.1mH 1.5% ±15d 1.5% ±50d ---
20.000H 1mH 1.5% ±15d 1.5% ±50d Parallel
200.00H 0.01H 2.0% ±10d 2.0% ±50d Parallel
2000.0H 0.1H 2.5% ±15d 2.5% ±50d Parallel
continued...