Use and Care Manual
12
Adjusting Emissivity
Theinstrument'semissivitycanbeadjustedfrom0.01to1.0tomeetthe
type of surface being measured. Refer to the Emissivity Chart for refer-
ence. Press the SET button three times to enter the emissivity setup. Press
the
button to toggle between emissivity preset values as indicated by
P1-P5. UsetheUP and DOWN buttons to set the emissivity values. Press
the UP and DOWNbuttonstoaddorsubtract0.01unitand/orholdthe
UP and DOWN buttons to add or subtract 0.1. The instrument will exit the
setup after 10 seconds of inactivity or if the trigger is pulled at any time.
Switching the Unit of Measure (°F/°C)
Press the SETbuttonfourtimestoenterunitofmeasuresetup.UsetheUP
and DOWNbuttonstoswitchbetween°Fand°Cunits.Theinstrumentwillexit
the setup after 10 seconds of inactivity or if the trigger is pulled at any time.
continued...