User guide
2
If you experience any difficulty with the installation or operation of your new
shower, then please refer to the “What to do if things go wrong” section in this
manual before contacting us.
CONTENTS
IMPORTANT SAFETY INFORMATION
Thank you for purchasing a quality Redring Expressions 570 Shower manufactured in England.
To enjoy your new shower at its best, please take time to read this manual thoroughly to
familiarise yourself with all instructions, BEFORE beginning installation.
1. Your shower has been designed for convenience, economy and safety of use, provided that it is
installed, used and maintained in good working order and in accordance with our instructions and
recommendations.
2. All wiring and installation must be supervised by a suitably qualified person.
3. THIS APPLIANCE MUST BE EARTHED.
4. The Redring Expressions 570 pumped electric shower is designed to heat and boost the flow
of stored domestic cold water, which is gravity fed from a static cold water cistern.
Under no circumstances should this unit be connected directly to the mains cold
water supply.
5. The cold water cistern should have a minimum capacity of 114 litres
(25 gallons).
There must be a minimum head of water of 8cm (3”) and a maximum head of 10m
(33ft) between the bottom of the cold water cistern and th
e top of the shower unit.
Under no circumstances should any of the pipework supplying the shower unit rise
above the level of the bottom of the cold water cistern.
6. The installation must be in accordance with the current edition of BS.7671 (the “IEE Wiring
Regulations”) and “Part P” of the “Building Regulations” in force at the time of installation.
Installations outside England and Wales must also conform to any local regulations in effect.
This appliance is intended to be permanently connected to the fixed electrical wiring of the mains
supply with its own dedicated supply.
7. This appliance must NOT be fitted where it may be subjected to freezing conditions
8. DO NOT switch the appliance on if you suspect it of being frozen.
Wait until you are sure it has thawed out.
9. DO NOT fit any sort of tap or control on the appliance outlet. The appliance is designed to have
an open outlet and should only be used with “Redring” recommended fittings.
10. Take care to avoid restricting the outlet of the pressure relief device. If water is discharged from
the pressure relief device, maintenance will be required before the appliance can be safely used.
11. Isolate the mains electrical and water supply before removing the front cover of the appliance.
Section
Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
How to install your Expressions 570 Shower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
How to maintain your Expressions 570 Shower . . . . . . . . . . . . . . . . . . . . . . . . . . . .
How to use your Expressions 570 Shower (Detailed) . . . . . . . . . . . . . . . . . . . . . . . .
What to do if things go wrong (1) Self Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Additional Accessories and Common Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . . .
What to do if things go wrong (2) Professional Service . . . . . . . . . . . . . . . . . . . . . . .
Redring After Sales Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
How your Expressions 570 Shower Works . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Filters and Assembly of Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Guarantee and Contact Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page
2
3
6
7
8
8
9
9
10
11
12
11
Diagram 10b
Chrome Models Riser Rail and Soap Dish
Fitting Instructions
(Refer to the separate fitting instruction sheet
packed with the accessories for more details)
1. Est
ablish height of riser rail to suit user
requirements.
This should be a maximum of 0.3 metres
(1ft) above the level of the heater,
see (a) below and Diagram 1 on page 3.
2. Remove covers from the wall brackets (b).
3. Position the lower bracket and mark the
wall for the screw fixing (c). Then drill and
plug the wall and fix the lower bracket
without the rail location notch.
4. Fit the rail into the lower bracket. Place the
remaining bracket with the rail location
notch on top of the riser rail, making sure
that the rail slot is located into the notch.
Ensure the hole position is vertically
aligned and mark the wall (d).
Remove the rail and bracket, then drill
and plug the wall.
5. Assemble the height adjuster (e).
6. Compress the height adjuster assembly
and slide onto the rail. Fit the hose
retaining ring and then the soap dish on
the bottom of the rail (f). Lock the soap
dish into position by tightening the lock nut.
7. Replace the rail assembly into the lower
bracket. Refit the top bracket, ensuring the
slot in the rail is located into the bracket
notch and fix to the wall.
Slide covers onto both brackets.
NOTE: The adjustable slider grips the conical nut on the
shower hose (g).
Inlet Assembly Removing the Filter from the Filtered
Showing Filter Position Isolation Valve (Turn water off first)
FILTERS
ASSEMBLY OF ACCESSORIES