User guide
2
CONTENTS
If you experience any difficulty with the installation or operation of your new
shower, then please refer to the “What to do if things go wrong” section in this
manual before contacting us.
Thank you for purchasing a quality Redring Expressions 520 Power Shower manufactured in England.
To enjoy your new shower at its best, please take time to read this manual thoroughly to
familiarise yourself with all instructions, BEFORE beginning installation.
1. Your shower has been designed for convenience, economy and safety of use, provided that it is
installed, used and maintained in good working order and in accordance with our instructions and
recommendations.
2. All wiring and installation must be supervised by a suitably qualified person.
3. THIS APPLIANCE MUST BE EARTHED.
4. The Redring Expressions 520 power shower is designed to boost the flow of stored domestic
water, which is gravity fed from a static cold water cistern and hot water cylinder.
Under no circumstances should this unit be connected directly to the mains cold or
hot water supplies.
5. The cold water cistern should have a minimum capacity of 114 litres
(25 gallons).
There must be a minimum head of water of 8cm (3”) and a maximum head of 10m
(33ft) between the bot
tom of the cold water cistern and the top of the shower unit.
Under no circumstances should any of the pipework supplying the shower unit
rise above the level of the bottom of the cold water cistern.
6. The Redring Expressions 520 power shower incorporates a motor that is designed for intermittent
use, and therefore, should NOT be used continuously for long periods of time.
The maximum length of time for any show
er should not exceed 15 minutes.
A rest period of 45 minutes is then required to allow the motor to cool down.
7. The installation must be in accordance with the current edition of BS.7671 (the “IEE Wiring
Regulations”) and “Part P” of the “Building Regulations” in force at the time of installation.
Installations outside England and Wales must also conform to any local regulations in effect.
This appliance is intended to be permanently connected to the fixed electrical wiring of the mains
supply with its own dedicated supply.
8. This appliance must NOT be fitted where it may be subjected to freezing conditions
9. DO NOT switch the appliance on if you suspect it of being frozen.
Wait until you are sure it has thawed out.
10. Isolate the mains electrical and water supply before removing the front cover of the appliance.
Section
Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
How to install your Expressions 520 Power Shower . . . . . . . . . . . . . . . . . . . . . . . . . .
How to use your Expressions 520 Power Shower . . . . . . . . . . . . . . . . . . . . . . . . . . . .
How to maintain your Expressions 520 Power Shower . . . . . . . . . . . . . . . . . . . . . . . .
Additional Accessories and Common Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . . .
What to do if things go wrong (1) Self Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
What to do if things go wrong (2) Professional Service . . . . . . . . . . . . . . . . . . . . . . .
Redring After Sales Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Filters Removal and Refitting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Assembly of Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Guarantee and Contact Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page
2
3
6
9
9
10
10
11
11
11
12
IMPORTANT SAFETY INFORMATION
11
REDRING AFTER SALES SERVICE
We offer a technical advisory service on the telephone to installers and other customers with
problems in the field. RING 0844 372 7766
Remember to quote the exact type of shower, as written on the front of the shower and on this
leaflet. The model and serial number are located on the bottom face of the shower.
Make a note of those numbers here, and be sure to quote them if you call for advice.
Model Number: _ _ _ _ _ _ _ _ _ _ _ _ _ Serial Number: _ _ _ _ _ _ _ _ _ _ _ _ _ _
Note: You may be charged for a service call if you do not have the serial number.
Inlet filters have been incorporated in the design of the Redring Expressions 520 power shower
which protects the internal mechanisms of the shower unit and the handset. If the performance of
the shower deteriorates (ie flow reduction occurs) then it may be necessary to clean the filters.
WARNING: SWITCH OFF THE ELECTRICITY AT THE LOCAL ISOLATOR
BEFORE REMOVING THE COVER TO MAKE CHECKS
Remove the shower cover as detailed in note 7 on page 4.
The cover will be connected to the PCB via a floating lead.
Carefully pull the lead from the PCB.
DO NOT let the front cover hang by the lead
as this will damage the PCB.
The filters are positioned in the inlet housing (Diagram 12).
Remove 2 fixing screws and the filter cap from the
housing and remove both filters. Wash thoroughly
under running water and replace in housing.
Ensure that both “O”-Ring seals are fitted to
the filter cap and reassemble cap using
2 fixing screws.
It may be necessary to re-prime the shower
unit after the filters have been cleaned.
Please refer to the commissioning procedure (see page 7).
Refit the front cover and Temperature Control Knob “B” as described in the commissioning procedure
FILTER REMOVAL AND REFITTING
ASSEMBLY OF ACCESSORIES