EBZ7150/RH 848-L6H-93A0 (001) U S OWNER'S/OPERATOR'S MANUAL BACKPACK BLOWER EBZ7150 EBZ7150RH WARNING The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. WARNING Before using our products, please read this manual carefully to understand the proper use of your unit. This spark ignition system complies with the Canadian standard ICES-002.
EBZ7150/RH SAFETY FIRST Instructions contained in warnings within this manual and warning seals marked with a symbol on the blower concern critical points which must be taken into consideration to prevent possible serious bodily injury, and for this reason you are requested to read all such instructions carefully and follow them without fail. Note that there may be times when warning seals peel off or become soiled and impossible to read.
EBZ7150/RH 1. Parts location 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. U S Frame Shoulder Strap Spark Plug Cap Throttle Lever Stop Switch (behind) Net Choke Lever Air Cleaner Volute Case “CAUTION” Label Elbow Fuel Tank Recoil Starter Ignition Switch Engine Cover Intake Cup [ EBZ7150RH ] 2. Specifications ■ MODEL EBZ7150/EBZ7150RH Dimensions (L x W x H) mm (in) EBZ7150·······································································································371x487x495 (14.
EBZ7150/RH 3. Warning labels on the machine (1) Read owner's manual before operating this machine. (2) Wear head, eye and ear protection. (3) Handling this machine improperly could result in accidents causing serious injury or death. Read this manual carefully and practice using the blower until you are fully acquainted with all operations and have learned to use it correctly. (4) Severing of fingers or hand by fan blade. Do not open or remove safety guards or nets while engine is running.
EBZ7150/RH 5. For safe operation WARNING • The blower is used for blowing away leaves and other debris on the ground. When operating the blower, the operater must stand with both feet firmly on the ground. Do not operate the blower while standing on a ladder or a stand. • Under no circumstances may the design of the machine be modified without the permission of the manufacturer. Always use genuine accessories and parts.
EBZ7150/RH 5. For safe operation WARNING 2. Before starting operation, always make sure to check if any obstacles are left inside the volute case and net. The obstacles may cause damage on fan and volute case and serious injury. 3. Check to see if the shock-absorbing rubber mount has become cracked or otherwise damaged.
EBZ7150/RH 5. For safe operation ordinances. 2. To reduce sound levels, limit the number of pieces of equipment used at any one time. 3. Operate power blowers at the lowest possible throttle speed to do the job. 4. Check your equipment before operation, especially the muffler, air intakes and air filters.
EBZ7150/RH 6. Set up F1 ■ BLOWER TUBES 1. Connect the blower and swivel joint with flexible hose. Clamp both ends of the flexible hose securely with the hardware supplied with the unit. 2. Align the protrusion and the groove provided on the tube ends and twist the tube until connection is locked up. NOTE F2 A light lubricant may be used to ease assembly of flexible pipe to blower elbow. F3 [EBZ7150RH] ■ THROTTLE LEVER [EBZ7150RH] • Set up the clamp to the swivel and tighten the screw on the clamp.
EBZ7150/RH 7. Fuel FUEL lines or fuel tank of the engine. WARNING • Gasoline is very flammable. Avoid smoking or bringing any flame or sparks near fuel. Make sure to stop the engine and allow it cool before refueling the unit. Select outdoor bare ground for fueling and move at least 10 ft (3 m) away from the fueling point before starting the engine.
EBZ7150/RH 7. Fuel test standard has been discontinued by API in 1995 and it no longer exists. IMPORTANT • Gasoline/Oil mixture Storage Recommendations Store your gasoline or gasoline/oil mixture in a cool dry area in a tightly sealed approved container to limit the entry of moisture and additional air (oxygen). Moisture and air cause the development of varnish and gum, making the fuel stale. Stored gasoline and gasoline/oil mixture ages and loses its octane rating and volatility.
EBZ7150/RH 8. Operation ■ CONTROL ARM [EBZ7150] (F5) • Hold the upper end of the control arm in hand and, while pulling it away from the unit, rotate arm forward (anticlockwise as the arrow direction) until it clicks. (The first position) And if you want, you can rotate arm more forward until it clicks. (The second position) Choose the arm position according to your working condition. • To fold the arm, reverse the order.
EBZ7150/RH 8. Operation ■ ADJUSTING THE SHOULDER STRAPS Tightening: • Pull on the end of the strap. F11 ■ STOPPING ENGINE [EBZ7150] • Move the throttle lever to the idling position and press the stop switch (red button). The machine has the mechanism that once the stop button is pushed the plug won't give off sparks until the engine stops. (F15) F15 [EBZ7150] (1) (1) Stop Switch Loosening: • Pull up on the lower portion of the buckle with a finger and slide the end of the strap back up to the buckle.
EBZ7150/RH 9. Maintenance Maintenance, replacement, or repair of the emission control device and systems may be performed by any non-road engine repair establishment or individual.
EBZ7150/RH 9. Maintenance F20 ■ SPARK PLUG • The spark plug may gather carbon deposits on its firing end with reasonable use. Remove and inspect the spark plug every 25 hours and clean the electrodes as necessary with a wire brush. The spark gap should be adjusted to .025 in (0.6~0.7mm). • Plug manufacturers recommend replacing the plug twice a year to avoid unexpected plug failure in a job.
EBZ7150/RH 9. Maintenance F25 ■ SHOULDER STRAP • If the shoulder strap is damaged it may break during use, thus causing the product to fall and resulting in personal injury. Follow the instructions below to replace the shoulder strap with new one. • Pass the upper end of the strap through the hanger, making the FLAPPED SIDE OUTSIDE. • Put the end of the strap through the ring on the strap, and then push the ring toward the hanger as close as possible.
EBZ7150/RH 10. Storage BEFORE STORING THE BLOWER: 1. Drain a fuel tank and push the primer bulb until it becomes empty of fuel. 2 .Remove the spark plug and drop a spoonful of 2-cycle oil into the cylider. Crank the engine several time and install the spark plug. 3. Store unit in a dry, dust free place, out of the reach of children. 11. Disposal • When disposing your machine, fuel or oil for the machine, be sure to allow your local regulations. 12. Troubleshooting guide Case 1.
EBZ7150/RH FEDERAL AND CALIFORNIA EMISSIONS CONTROL WARRANTY STATEMENT YOUR WARRANTY RIGHTS AND OBLIGATIONS U S The EPA (U.S. Environmental Protection Agency), CARB (California Air Resources Board), Environment Canada and RedMax are pleased to explain the emissions control system's warranty on your 2009 and later small off-road engine. In U.S.
EBZ7150/RH warranty is warranted for the remaining warranty period. Any warranted part that is scheduled only for regular inspection in the maintenance schedule will be warranted for a period of two years. A statement in such written instructions to the effect of "repair or replace as necessary" will not reduce the period of warranty coverage. Any such part repaired or replaced under warranty will be warranted for the remaining warranty period.