2.8. Restricted Frequency Bands
2.8.1. Requirement
According to FCC section 15.247(d), in any 100kHz bandwidth outside the frequency band in
which the spread spectrum or digitally modulated intentional radiator is operating, the radio
frequency power that is produced by the intentional radiator shall be at least 20dB below that in the
100kHz bandwidth within the band that contains the highest level of the desired power, In addition,
radiated emissions which fall in the restricted bands, as defined in 15.205(a), must also comply
with the radiated emission limits specified in 15.209(a).
2.8.2. Test Description
Test Setup
The EUT is located in a 3m Semi-Anechoic Chamber; the antenna factors, cable loss and so on of
the site as factors are calculated to correct the reading.
For the Test Antenna:
Test Antenna is 3m away from the EUT. Test Antenna height is varied from 1m to 4m above the
ground to determine the maximum value of the field strength.