70-00072-01-10 Proprietary Redline Communications © 2011 Page 76 of 152 March 2, 2011
End: Upper limit of the frequency scan interval (MHz).
Remote Frequency Ranges
If values have been downloaded, these settings will be used when recovering from a
loss of registration. This list is not saved permanently, and is discarded when the unit
is rebooted.
Controls
Reload: Reload and display the saved (Local) scan intervals. Unsaved changes are
discarded.
Test: Check the validity of the current range settings in the Local Frequency Range
list. This action does not
save the changes. An event message is logged indicating
the results of the range validation test.
Save: Check the validity of the current range settings in the Local Frequency Range
list and save these settings in non volatile memory. An event message is logged
indicating the results of the range validation test.