70-00072-01-10 Proprietary Redline Communications © 2011 Page 75 of 152 March 2, 2011
5.3.3 Frequency Range Settings
Frequency Ranges: C
Click the blue text Frequency Ranges (on the system configuration screen ) adjacent to
the Auto Scan selection to display the Frequency Management screen. Up to 32
frequency ranges may be entered. Settings entered on the PTP Master (PMP SC) will be
downloaded and used by the PTP Slave (PMP SS) if Auto scan is enabled.
Fig. 46: Web - Frequency Management Screen
Add Frequency Range
Begin: Enter the lower limit of the frequency scan interval (MHz). The scan interval
must be a subset of the region frequency range. The unit automatically compensates
for channel size when selecting the center frequency.
End: Enter the upper limit of the frequency scan interval (MHz). The scan interval
must be a subset of the region frequency range. The unit automatically compensates
for channel size when selecting the center frequency.
Add: Click to save the new range settings in the Local Frequency Range list. This
action does not check the validity of the specified range (see Test and Save buttons
at the bottom of the screen).
Delete Frequency Range
Index: Choose the index value of the scan interval to be deleted from local frequency
range table.
Delete: Click the Delete button to permanently remove the selected scan interval
from the local frequency range table.
Local Frequency Ranges
These settings are saved in non-volatile memory and will be loaded when the unit is
rebooted.
Index: Index value of this entry in the local frequency range table.
Begin: Lower limit of the frequency scan interval (MHz).