by the subscriber (displayed as Remote Frequency Ranges on the subscriber). The
downloaded range settings are used exclusively by the subscriber during autoscan and
remain in effect until the subscriber is rebooted (setting are discarded at reboot.
PMP SS: When no frequency ranges are entered (default), the subscriber scans all
available frequency ranges for that region (refer to 9.5: Regional Codes on page
144). When one or more frequency ranges have been entered (or downloaded from
the sector controller), only these frequency ranges are scanned. If all entered
frequency ranges are scanned (x3) without registering with a sector controller, the
subscriber defaults to scanning all enabled frequencies.
System Mode: The system designated as sector controller establishes and manages
the bi-directional data link with a remote end AN-80i. Only one system in a wireless link
must be set for Sector Controller mode (PMP SC).
PMP SC: AN-80i begins transmitting automatically, sends poll messages to locate
and register remote AN-80i subscribers, and negotiates operating settings for the
link.
PMP SS: AN-80i monitors the selected channel(s) until polled by the PMP Sector
Controller.
Registration Period: The polling period for detecting new subscribers. This period is
based on the number of wireless frames transmitted. Permitted values are 1 to 400
frames. It is recommended to use four frames as the default registration period.
Max. Distance [km]: Enter the distance to the subscriber located farthest away from the
sector controller (outer boundary of sector). This parameter is used to optimize
communications with the subscribers.