User manual
AN-80i User Manual
70-00072-01-10 Proprietary Redline Communications © 2011 Page 40 of 152 March 2, 2011
Link is being monitored by the Redline Management System (RMS).
Link Name: Enter the shared name to uniquely identify this wireless link to both the local
and remote-end systems.
On power-up/reboot or auto scan following deregistration or DFS event, the wireless link
will only be established between two units having identical link names. The name may
be blank or contain up to thirty (30) alpha-numeric characters including a-z, A-Z, 0-9,
dash (-), and underscore (_).
Important: A PTP wireless link can be established only between pairs of AN-80i or
AN-80i-AN-50e systems having identical Link Name settings. The AN-80i Link Name
field must be blank (delete all characters) to establish a wireless link with an AN-50e.
X509 Authentication Enable: Check this box to require authentication using an
installed X.509 certificate. The user-defined unit certificate, authority certificate, and RSA
private key must be downloaded using the CLI 'load' command. Uncheck this box to
allow network connections without requiring authentication.
Note: AN-50e systems do not support X.509 authentication.
FIPS Mode Enable: Check this box
to enable FIPS mode. The unit will enter FIPS
mode only if the AN-80i is configured according to the FIPS standards. In FIPS mode,
only FIPS approved algorithms are used for SSH, HTTPS and wireless security.
Notes:
1. HTTPS (SSL) is not available until an X.509 certificate and DSA private key have
been loaded (ssl_cert_<mac>.pem and ssl_key_<mac>.pem).
2. AES encryption is not available until the X.509 certificate and key files have been
loaded (usr_wacert_<mac>.der, usr_wcert_<mac>.der, and usr_wkey_<mac>.der).
3. FIPS X.509 certificates can be loaded only
when the AN-80i is in FIPS mode.
Configuration Controls
Save: Click to activate and permanently save changes made in this screen. Changes to
some parameters cause a system reboot when the Save button is selected. If the Save
button is not clicked, all unsaved changes will be discarded on the next system reboot.
Test: Click to activate the changes made in this screen for a period of five minutes.
During this test period, click the Save button at any time to permanently save the running
configuration and disable the timer. If the Save button is not
selected before the timer
expires, the AN-80i is rebooted using the last saved configuration.
Reboot: Click to immediately reboot the AN-80i. All statistics are reset and unsaved
changes are discarded. Operator confirmation is required.
Def Cfg: Click to overwrite the current saved configuration with the factory default
settings. The AN-80i will reboot. Operator confirmation is required.
Chg Ver: Click to change to the other saved version of software (System Version field)
and reboot. Operator confirmation is required.
4Gon www.4Gon.co.uk info@4gon.co.uk Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299