User manual
AN-80i User Manual
70-00072-01-10 Proprietary Redline Communications © 2011 Page 20 of 152 March 2, 2011
2.5.2 DC Power Adapter
The DC power adapter input is auto-sensing 18 - 60 VDC.
Fig. 4: Intro - Indoor Power-over-Ethernet (PoE) Module - DC Model
Warning to Service Personnel: 48 VDC
Customer equipment including personal computers, routers, etc., must be connected
only to the INPUT (DATA) port on the PoE unit.
Only the outdoors Ethernet interface cable connecting to the AN-80i can be safely
connected to the OUTPUT (DATA & POWER) connector. Connecting customer
premises Ethernet equipment directly to the OUTPUT (DATA & POWER) connector
on the Power-over-Ethernet power adapter may damage customer equipment.
2.6 Antenna Alignment
The AN-80i includes both an audible alignment tool and a web-based alignment tool to
assist in pointing the antenna.
2.6.1 Web Page Alignment
The web page can be accessed directly from a link on the System Status screen
(Antenna Alignment).
The most reliable method for obtaining optimum performance from a wireless link is by
fine alignment of the antenna to the position providing the highest RSSI (Received
Signal Strength Indication) and best SINADR (Signal to Noise And Distortion Ratio). The
web page assists alignment by providing continuous 1-second updates of RSSI and
SINADR values.
Fig. 5: Intro - Web Antenna Alignment Tool
If Wi-Fi service is available, you may also be able to access the web alignment page
directly from a laptop computer and most web-enabled handheld devices using the
following URL:
http:// [AN-80i IP Address] / usr / aa.html
For example: http:// 192.168.20.25 / usr / aa.html
Note: SINADR is available only on PTP systems.
4Gon www.4Gon.co.uk info@4gon.co.uk Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299