User manual
AN-80i User Manual
70-00072-01-10 Proprietary Redline Communications © 2011 Page 149 of 152 March 2, 2011
9.7 ID Map
Beginning with v13.xx, all IDs must comply to ranges listed in the following table. The
'load script ...' command rejects all ID references greater than 511.
Table 78: Spec. - Provisioning Table ID Ranges
Provisioning Type Version 10.xx to 12.xx Version 13.xx
ID Range ID Range
Link 4 - 63
Group 4 - 1024 64 - 95
Connection 95 - 511
Note: When the v13.xx software is run for the first time only, all existing provisioning IDs
in the range 4 - 511 are automatically mapped to the new schema. All ID references
greater than 511 are discarded.
4Gon www.4Gon.co.uk info@4gon.co.uk Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299