70-00072-01-10 Proprietary Redline Communications © 2011 Page 112 of 152 March 2, 2011
Table 50: Diag. - PMP Status Codes
Bit
Description
1
Radio over-temperature
4, 5, 6
PLL Errors
8
Firmware Error
16
No Ethernet packets received by the wireless MAC
17, 18, 19, 20, 21, 22,
23, 24, 25, 26, 27, 28
MAC Internal Errors
7.4.3 FIPS Status Codes
The PMP status code is displayed in a series of hexadecimal characters representing
the status of different alarm conditions. The value '1' indicates the associated condition
is active. All unused bits are set to zero.
Table 51: Diag. - FIPS Status Codes
0x0001
Power up self test for random number generator failed
0x0002
Power up self test for 3DES failed
0x0004
Power up self test for AES (communication channel) failed
0x0008
Power up self test for SHA failed
0x0010
Power up self test for HMAC failed
0x0020
Power up self test for DSA failed
0x0040
Power up self test for RSA failed.
0x0080
Power up self test for AES (data channel) failed
0x0100
Continuous self test for random number generator failed