User manual
AN-80i User Manual
70-00072-01-10 Proprietary Redline Communications © 2011 Page 106 of 152 March 2, 2011
6. Reboot the unit to exit from long reset mode.
Notes:
7. If a login prompt does not appear in step 4, re-enter the Telnet command during the
30 second interval until the command prompt appears. If this is not successful,
repeat steps 1 to 4 using an initial wait time of 70 to 90 seconds).
8. When the operator performs a login (Telnet or Web browser) during a long reset
session, the usernames and passwords for the administrator and user are
automatically reset to default values. All other user accounts are deleted.
9. If the operator does not login during step 5, the AN-80i will reboot automatically and
be fully operational (with no changes) within two minutes.
Refer to page 118 for a complete description of this feature.
7.1.2 Restore Default Passwords Only
Use this procedure if the unit IP address is known and it is desired only to restore the
default usernames and passwords. All other configuration settings are preserved.
Telnet
1. Perform a long reset and use Telnet to login to the AN-80i using the default IP
address (192.168.25.2), and the default administrator username (admin) and
password (admin).
2. Enter the command reboot to restart the unit. Do not enter any other commands.
3. Login to the AN-80i using the user-configured IP address and the default
administrator username (admin) and password (admin).
Web
1. Perform a long reset and use a Web browser to login to the AN-80i using the default
IP address (192.168.25.2), and the default administrator username (admin) and
password (admin).
2. Click Configure System to display the System Configuration screen.
3. Click on the Reboot buttons at the bottom of the screen to reboot the AN-80i.
4. Login to the AN-80i using the user-configured IP address and the default
administrator username and password (admin/admin).
7.1.3 Restore Factory Configuration
Use the following steps to restore the AN-80i to the factory configuration
Telnet
1. Perform a long reset and use Telnet to login to the AN-80i using the default IP
address (192.168.25.2), and the default administrator username (admin) and
password (admin).
2. Enter the command save defaultconfig. The AN-80i will automatically reboot.
3. Wait for the reboot to complete (10 seconds) and login to the AN-80i using the
default IP address (192.168.25.2) and the default administrator username (admin)
and password (admin).
Web
1. Perform a long reset and use a Web browser to login to the AN-80i using the default
IP address (192.168.25.2), and the default administrator username (admin) and
password (admin).
2. Click Configure System to display the System Configuration screen.
3. Click on the Def Cfg button at the bottom of the screen to reload the factory settings
and automatically reboot the AN-80i.
4Gon www.4Gon.co.uk info@4gon.co.uk Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299