User manual
& User
AN-80i
Manual
70-00072-01-08b Proprietary Redline Communications © 2009 Page 89 of 128 June 4, 2009
Table 30: CLI - set
PTP PMP Parameter/Description
it will not be possible to use the CLI interface.
off - Disable
on - Enable
Changes to this field are effective only following reboot.
telnetport <value>
Enter Telnet port address (default is 23).
x509auth <on | off>
Enable or disable authentication.
off - Allow network connections without authentication.
on - Require authentication using X.509 certificates.
√
View and change PMP parameter settings.
set <parameter>
activekey <key_#> <key_value>
Enable or disable the adaptive modulation function.
key_# - Options key position: 1 or 2.
key_value - Options key.
autoscan <on | off>
Enable or disable the Autoscan function.
off - Disable
on - Enable
When enabled, the PTP Subscriber (system mode) AN-80i
automatically scans available channels to locate the current
operating frequency of the PTP Sector Controller system.
Executing a set command this field on a PTP Sector Controller
will generate an error message.
bsporten <id> <mode: on | off>
Sector controller Ethernet port enable.
id - ID of port
mode - Set state of port.
off - Disabled
on - Enabled
buzzer <on | off>
Enable or disable the audible alignment buzzer. When enabled,
the rate of the tone is proportional to the receive signal strength
(faster = stronger signal).
off - Disable
on - Enable
chwidth <value>
Enter the channel bandwidth in MHz. Valid entries are 10, 20,
and 40.
congid <id> <gid>
Connection's group ID.
id - [id number]
gid - gid
conlid <id> <lid>
Connection's Link ID.
id - [id number]
lid - lid
conpri <id> <pri>