User manual
& User
AN-80i
Manual
70-00072-01-08b Proprietary Redline Communications © 2009 Page 53 of 128 June 4, 2009
4.5 PMP Quick Configuration Example
This chapter is provided to aid configuration of point-to-multipoint (PMP) AN-80i
systems. The procedures provided below include steps to setup a basic working
configuration for initial testing, and then to introduce VLAN traffic filtering. No Ethernet
data traffic can be transmitted over the wireless interface before completing this setup.
Figure 28: Web - PMP - Pass-through Only Deployment
Configure Pass-Through Operation
Configure a PMP configuration without VLAN support.
Step I: Create Subscriber Links
1. Click New Link in the main menu to add a subscriber link.
2. Enter a unique name for this link in the Link Name field.
3. Enter the subscriber MAC address in the Peer MAC field.
4. Refer to the link budget for each subscriber and enter the desired UBR rates in the
Max. DL Burst Rate and Max. UL Burst Rate fields.
5. Click Apply to save and activate settings.
Repeat steps 1 - 5 to add additional links.
Step II: Create Pass-through Group
1. Click New Group in the web page main menu to create a group.
2. Enter a unique name for this group in the Group Name field.
3. Select Pass-through for the Group tagging mode field.
4. Check the SC Ethernet Enable box .
5. Enter the value 5 for the Group QoS Level (0 disables multicast).
6. Click Apply to save and activate the pass through group settings.
Step III: Create Subscriber Connections
1. Click New Connection to add a connection for a subscriber.
2. Enter a unique name for this connection in the Connection Name field.
3. Select Pass through in the Connection tagging mode field.
4. Enter the Link ID for this subscriber in the Parent Link ID field. Click the Links List
text to select from the list of links created in step I.