Appendix D Camera Timing
ES 1020 Timing Specifications
Free Run Electronic Exposure One Tap Two Tap
Master Clock
34.4Mhz - 29ns period 34.4Mhz - 29ns period
Frames/Sec
28.37 48.83
H Active Pixels
1004 502 x 2 Taps
H Count
1194 692
H Active Time
29.24us 14.65us
H Sync Time
5.561us 5.561us
H Line Time
34.9us 20.21us
V Active Lines
1004 1004
V Count
1010 1010
V Active Time
34.98ms 20.31ms
V Sync Time
269.3us 167.1us
V Frame Time
35.24ms 20.48ms
Free Run Timing
Yellow = FVAL, Green = LVAL, Blue = Tap L, Red - Tap R