Timing Generator
02 00 TG Timing Read/Write 0x3b54
02 01 TG Control Read/Write 0x0000
02 02 TG Partial Scan Start Read/Write 300
02 03 TG Partial Scan Stop Read/Write 900
02 04 Transfer Pulse Delay Read/Write
02 05 Transfer Pulse Width Read/Write
02 06 TG Firmware Revision Read
02 07 TG Invert Signals Read/Write 0x0000
02 08 Reserved
02 09 Reserved
02 0a TG Exposure Read/Write 1150
Memory Management
03 00 Save Camera State to User
EEPROM
Write
(dummy
data, correct
checksum)
NA
03 01 Load User EEPROM to Camera
State
Read (end
and ack only)
NA
03 02 Save Camera State to Factory
EEPROM
Write
(dummy
data, correct
checksum)
NA
03 03 Load Camera State from
Factory EEPROM
Read (end
and ack only)
NA
03 04 Load Current Camera State
from ROM
Read (end
and ack only)
NA
03 05 Read EEPROM Location Read
03 06 Reload Xilinx and restart
camera
Write
03 07 Save Tap Matching Array to
Fact and User EEPROM
Write 0x0000 = Save Gain =1 to user and
factory
0x0001= Save Gain = 2 to user and
factory
0x0002=Save Gain = 4 to user and
factory
0x0003 = Save Gain = 8 to user and
factory
03 09 Save tuning data to Factory
and User EEPROM
Write 0x0000 = Save un binned timing to
factory and user EEPROM
0x0001 = Save hbinx2 tuning to
factory and user
0x0002 = save hbinx4 tuning to
factory and user
03 0a INIT camera no Xilinx reload Write
03 0b Soft INIT Xilinx Write 0x0000 = Normal operation
0x0001 = Init state machines