Appendix C Advanced Functions
Timing Generator Control Register 1
15 14 13 12 11 10 9 8
TRIGGER
POL
PARTIALSC
AN EN
FLIP BITS SINGLE TAP TRIGGER
ENABLE
TME
ENABLE
TDE
ENABLE
RESERVED
7 6 5 4 3 2 1 0
TEST
PATTERN
ENABLE
TG SOFT
RESET
8 Bit CL
output
TAP FLIP VBIN
4/2
VBIN
ENABLE
HBIN
4/2
HBIN
ENBLE
• TRIGGER POL(ARITY)
Set to 0 for negative trigger pulse
Set to 1 for positive trigger pulse
• PARTIAL SCAN ENABLE: Single tap output mode for testing
Set to 1 to enable operation
• FLIP BITS: Flips data bits from msb to lsb
Set to 0 to enable msb in bit 0
Set to 1 to enable lsb on bit 0
• SINGLE TAP: Single/Dual tap readout selection
Set to 1 to enable single tap operation
Set to 0 to enable dual tap operation
• TRIGGER ENABLE: Select Trigger mode of operation
Setting this bit to 1 will cause the TG to enter the external trigger mode
• MANUAL EXPOSURE: Manual trigger mode selection
Set to 1 to enable single tap operation
Set to 0 to enable dual tap operation
• TDE ENABLE: Trigger Double Exposure Enable
Set to 1 to enable TDE mode
Set to 0 to disable TDE mode
• TEST PATTERN ENABLE:
Setting this bit to 1 will cause the TG to output a fixed gray pattern with grid overlay.
Set to 0 to disable the test pattern
• TG SOFT RESET: Timing Generator State Machine Reset
Set to 1 to re-initialize TG state machine
Set to 0 to resume normal operation
• 8 Bit CL Output (SINGLE TAP ONLY)
Setting this bit re maps the camera link output to 8 bits per tap.
The 8 most significant bits of the ADC are used.
• TAP FLIP
Setting this bit to 1 will cause the TG to flip taps.