User`s manual

REDLAKE MASD, INC.
3.6 Alphabetical Command Summary
NOTE: The commands listed below can be entered in either upper or lower case.
FUNCTION COMMAND ARGUMENT RANGE PAGE
Alternate Correction Table ACT 0, 1 3-8
Binning Set BNS 1 (2K), 2 (1K), 3 (512) 3-4
Defect Conceal DEF on, of 3-8
Digital Gain DGN 1, 2, 4, 3-7
Display Wedge WDG on, of, 0, 1, 2, 3 3-9
Exposure (Triggered) EXE .091 to 112.298; increment=0.063mS 3-5
Exposure (2Kx2K) EXE .091 to 64.956; increment=0.063mS 3-5
Exposure (1Kx1K) EXE .092 to 32.495; increment=0.063mS 3-5
Exposure (512x512) EXE .097 to 16.6135; increment=0.058mS 3-5
Fast Read Mode FAS on, of 3-10
Frame Rate Set FRS 4, 8, 15, 30, and 60 (used with Remote
Control Panel software)
3-5
Gain Select GAS 0, 1, 2, 3 3-7
Identification Query IDN? (no argument required) 3-11
Look Up Table LUT on, of 3-7
Mode Command MDE CS, CD, TR, DE, CF 3-4
Offset and Gain Coefficient OGC on, of 3-7
PSC Command PSC on, of 3-10
Readout Channels RDM 1, 2 3-2
Reset RST 0 to 9 3-9
Save SAV 0 to 9 3-8
Serial Communication SCP 232, 422 3-10
Smear Correction SMC on, of 3-10
Strobe Polarity STP p, n 3-8
Status Query STS? (no argument required) 3-11
Temperature Query TMP? (no argument required) 3-11
Transfer Pulse Delay TPD 1 to 999; increment=0.2µs 3-6
Transfer Pulse Width TPW 1 to 10 (MDE=DE) 3-7
Transfer Pulse Width TPW 12 (MDE=CS, CD, or TR) 3-7
Trigger Expose TRE 0, 1 3-6
Trigger Polarity TRM p, n (May use TRP for same command) 3-6
Trigger Source TRS AIA, EXT, SW 3-6
91000116-001 Revision B 3-12 10/15/02