Installation Guide

RDQCI5029 Rev. 0 Page 6 Cered 06/01/2016
Wipe the shower walls and sill, the curb [A] and
the wall jambs [B
] with a clean, dry cloth to remove
any dust or debris. Apply a 1/4” bead of caulk along the
inside of both of the pencil lines marked in Step #2
.
Carefully replace the curb in the exact position marked.
Caulk th
e inside of the curb ends where they meet
the wall.
Replace both wall jambs and attach to the
walls with six #8 x 1 1/2” truss head screws [D].
4
#8 x 1/2”
SCREW
WALL
JAMB
CURB
CAULK
WEEP SLOT
TO INTERIOR
Place two setting blocks [E] into the curb [A] to
support the fixed glass panel [F]. Position the b
locks 3”
from each corner of the glass panel. Set the glass panel
into place on the setting blocks and approximately 1/2”
into the wall jamb [B
]. A strip of masking tape 1/2”
from each vertical edge of the glass will aid alignment.
NOTE: Obscure or etche
d glass panels should be
installed with the rough or patterned surface of the
glass to the exterior of the unit.
Press the 180° post [G
] into the curb and position to
overlap the glass panel by 1/2”. Use masking tape to
hold the post in position temporarily.
NOTE: To facilitate out-of-
plumb walls, the 1/2” glass
bite may be varied from 1/4” to ¾”.
5
WALL
JAMB
1/2”
GLASS
PANEL
1/2”
180
POST
GLASS
PANEL
CURB
SETTING
BLOCK
Measure the wall-to-wall opening at the top of
the wall jambs [B] and cut the header [H
] to fit the
exact opening. Using a 3/16” drill bit, drill the interior
face of the header on both ends as shown. These holes
may be pre-drilled from the factory.
6
ROIRETNI
MEASURE AT TOP
OF WALL JAMB
8/3
1/4”
HEADER
.AID 61/3
L E NA P S S A L G
RDQCI5029 Rev 0 Page 5 Certified 06/21/2016