Installation Guide
RDQCI5023 Rev. 0 Page 6 Cered 06/01/2016
WALL
JAMB
 NYLON
SPACER
 1 1/2” TRUSS
HEAD SCREW
HEADER
WALL
JAMB
 ROLLER
BEARING
 3/8” HEX
HEAD SCREW
 ROUGH
SURFACE
 ROUGH
SURFACE
 ROLLER
BEARING
EXTERIOR
 GLAZED 
DOOR PANEL
4 Replace one wall jamb and attach it to the wall 
with two #8 x 1 1/2” truss head screws [D] inserted into 
the top and bottom holes.
Slip a nylon spacer [E] over a #8 x 1 1/2” truss head screw 
and insert it into the center hole of the wall jamb. Double 
check wall jamb for plumb and tighten the screws.
NOTE: Do not overtighten the screws.
5 This enclosure is equipped with safety “T” lock 
wall jambs. When properly installed, the header is 
permanently locked to the wall jambs and cannot be 
accidently dislodged.
Measure the wall to wall opening at the top of the wall 
jambs and cut the header 1/16” short of this dimension. 
Check the header for fit.
Slide the safety “T” lock of the unmounted wall jamb 
into the end of the header. The header is reversible so 
that either face may be turned to the exterior of the unit. 
Holding the header at an angle, slide it over the “T” lock 
of the mounted wall jamb. Pivot the header into place and
slide the loose wall jamb to the wall and press it into 
position on the bottom track.
Attach the jamb to the wall per instructions in Step #4.
6  NOTE: Obscure or patterned glass should be
installed with the rough or textured surface of the
glass to the exterior of the unit.
Units with obscure or patterned glass, there is an
interior and exterior door panel [G] as determined
by the position of the top fin with the angled slots.
Door panels with clear glass are interchangeable
unless they have been treated with Aquaglide.
Attach the four nylon roller bearings [H] to the door 
panels, as shown, using the #8-32 x 3/8” hex head
screws [J]. Center them in the outside slots of the
top fins.
RDQCI5023 REV. 0
Page 5
Certified 06/22/2016