Installation Guide

RDQCI5285 Rev. 0 Page 7 Cered 06/01/2016
RDQCI5285 Rev 0 Page 7 Cered 06/17/2016
Place 1/8” setting blocks as shown or approximately every 18”. DO NOT
place setting blocks over screw heads. Using suction cups slide the
Fixed Panel Glass into the appropriate side. Use setting blocks to make
exposed edges of the glass level and plumb. Exposed edges MUST be
level and plumb before moving to next step.
Using the glass clamp mounting hole on the Fixed Panel Glass as a
guide, make a mark on the wall on center w/ the hole. Remove the
Fixed Panel Glass and carefully set aside, leaving the setting blocks in
position.
**Different size setting blocks may be required depending on level condi-
tions. Various size setting blocks are provided and can be used in differ-
ent combinations (stacked) to obtain the desired results.
Insert a small amount of silicon into each drilled hole, then insert a wall anchor into each hole.
(Note: Drill hole, then insert a wall anchor.) This must be done just before u-channel installation.
Carefully cut the heads off the wall anchors with a razor blade. Place the U-Channel in correct posi-
tion and secure it with #8 x 1-1/2” truss head screws.
HOLE
MARK ON
WALL
WALL ANCHORS
Threshold / Shower base
Silicone
Note: Do not over tighten screws.