Use and Care Manual

www.sureheat.com
5200319-01C
SPECIFICATIONS
Model IWH16NLTD-2 IWH26NLTD-2
Ignition
Gas Type Natural Propane Natural Propane
BTU/Hr Input Max. (available)
20,000 18,000 30,000 28,000
Pressure Regulator Setting 6" W.C. 10" W.C. 6" W.C. 10" W.C.
Inlet Gas Pressure*
(inches of water)
Max. 9.5" Max. 14" Max. 9.5" Max. 14"
Min. 7" Min. 11" Min. 7" Min. 11"
Heater Dimensions (HxWxD) 24.1" x 18.46" x 8" 24.1" x 25.5 x 8.46"
Carton Dimensions (HxWxD) 26.18" x 20.7" x 9.84" 26.18" x 28.15" x 9.84"
Heater Weight 23.6 lbs 29.7 lbs
Shipping Weight 27.4 lbs 34 lbs
Electrical Requirement for Blower Kit (if equipped)
Voltage • 120 VAC, 60 Hz
Note: Dimensions listed are outer most points on the heater (includes control
knobs and grill).
* For purposes of input adjustment.
LOCAL CODES
Install and use heater with care. Follow all
local codes. In the absence of local codes,
use the latest edition of The National Fuel
Gas Code, ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
25 West 43rd Street
New York, NY 10036
National Fire Protection Association, Inc.
1 Batterymarch Park
Quincy, MA 02269-9101
This heater is designed for vent-free op-
eration. State and local codes in some areas
prohibit the use of vent-free heaters.
State of Massachusetts: The installation
must be made by a licensed plumber or
gas tter in the Commonwealth of Mas-
sachusetts.
Sellers of unvented propane or natural
gas-red supplemental room heaters shall
provide to each purchaser a copy of 527
CMR 30 upon sale of the unit.
In the State of Massachusetts the gas
cock must be a T-handle type. The State
of Massachusetts requires that a exible
appliance connector cannot exceed three
feet in length.