User Manual
www.redbackaudio.com.auRedback® Proudly Made In Australia8
Redback® A 4275C/85C 125/250W Mixer Amplier
Overview
1.6 LED STATUS INDICATORS
There are two led’s on the front panel which indicate when power is available and if there is a fault.
The fault led will turn on under the following conditions.
Overtemp
When the amplier reaches a dangerous temperature the unit will shutdown, preventing damage. If this occurs, check for
short circuits on the speaker line or objects blocking the ampliers air vents.
1.7 PROTECT MODE
If the amplier reaches a critical temperature or is over-driven it will shutdown.
The amplier has been designed with an in built protection mode which will throttle the amplifer back to 50% output if it
nears the shutdown temperature.
If the Protect Mode is active the amplier LCD will ash “ON” and “OFF” to highlight that there is a problem with the
amplier. The fault condition will be displayed on the screen.
1.8 LCD STATUS INDICATORS
The LCD is used to offer more detailed information about the status of the amplier.
The following elements can all be indicated on the display but may not be visible unless required.
• Signal presence
• Master Volume Level
• Amplier Output level in dB
• Remote volume level
• Current Limit Condition
• Voltage Limit Condition
• Heatsink Temperature
• 230V AC Presence
• 24V DC Presence
• Alert/Evac Activation
1.9 LCD OVERVIEW
Fig 1.9 shows the layout of the LCD.
1 Zone Label
The Amplier can be given a specic name so it is easily distinguishable. (Eg Sports Bar,Level 5 etc)
(see section 1.10 for more details).
2 Mains Status Indicator
Indicates when the unit has mains power.
3 24V DC Status Indicator
Indicates when the unit has a 24V DC backup supply connected.
4 Heatsink Temperature Indicator
Displays the temperature of the internal heatsink.
5 Protect Mode
If the amplier reaches a critical temperature the amplier will go into protection mode.
6 Current Limit Indicator
If the amplier goes into an over current status this indicator will come on. (see section 1.6 for more details)
7 Voltage Limit Indicator
If the amplier goes into an over voltage status this indicator will come on. (see section 1.6 for more details)