Manual

9 SOLAR BLANKET SETUP
REDARC Amorphous and SunPower
®
Cell solar blankets features reinforced eyelets at the four
corners and sides of the panel to allow for various mounting options. These panels can also
be setup across your vehicle, caravan or tent and can be used to provide shade as well as
performing their power generating function.
9.2 FUSE PROTECTION
Fuse protection is required for wire and component protection in case of short circuit.
Fuses are to be fi tted as close as possible to the battery positive terminal.
REDARC recommend using MIDI style bolt down fuses as they ensure a low resistance
connection. The REDARC FK40 and FK60 fuse kits are recommended.
Blade type fuses are not recommended as they can result in high resistance connection
which causes excess heat and may damage the fuse holder and/or the wiring. Self-
resetting circuit breakers are not recommended as they may trip prematurely due to the
heat generated by the current fl owing through the wires.
13