Product Manual
3 MONITOR INFORMATION
Batt. AH The Battery amp hours can be set to offer a state of charge percentage, the
range is from 1 - 9999Ah.
Note1: This a calculated guide available on the Battery Information page 3.
Note2: This setting is a guide only, the battery size does not need to be set
for correct function/charging.
Temp Comp. Coeff
This screen shows and allows changes to the Temperature
compensation coefficient and systems rated voltage:
Temp Comp. The temperature coefficient is the reduction in voltage (millivolt)
per degree Celsius rise in temperature.
Rated Voltage The battery nominal voltage (12v, 24v or Auto)
Over Volt Disc.
This screen shows the Over Voltage Disconnect and Charge voltage
limit setting:
Over Volt Disc. The battery voltage level that will disconnect the solar panel and stop
charging the battery
Charge limit The highest charging voltage allowed to be set.
Over Volt Rec.
This screen shows the Over Voltage Reconnect voltage setting and
the Equalisation charge state:
Over Volt Rec. The battery voltage level that will reconnect the solar panel to the battery
and resume charging after a previous high voltage disconnection
Equal. Charge The Equalisation charging stage voltage setting.
Note: this will be zero for AGM battery setting and two 2 hours for Calcium and Standard
battery types)
Absorb. Charge
This screen shows the Absorb & Float charging stage voltage levels:
Absorb Charge The battery voltage limit for the Absorb Stage of charging, Absorb stage is
when the battery is approaching full and the regulator is maintaining a
constant output voltage.
Float Charge The battery voltage limit for the Float stage of charging, Float stage is
when the battery is full and will be trickle charged from the solar panel.
Temp Comp. Coeff
Rated Voltage
Auto
-
3mv/°C/2V
Over Volt. Disc.
Charge Limit
16.0V
16.5V
8
Over Volt. Rec.
Equal. Charge
----V
15.8V
Absorb. Charge
Float Charge
13.6V