Product Manual

3 MONITOR INFORMATION
3.3 DEVICE INFORMATION
Device Information (2 Screens)
These screens show the regulators default ratings and serial
number:
Rate. Vol The regulators rated voltage 12 or 24v
Char. Cur The regulators rated charging current
SN Internal serial number (REDARC use only)
3.4 CONTROL PARAMETERS
To change settings, press the ‘OK’ button, enter the device password and press ‘OK’
again. Change the setting to the desired value and press ‘OK’ once more to save the
setting.
Check the manufacturer’s data for your battery and ensure that the Absorption’
voltage of the profile selected does not exceed the manufacturer’s recommended
maximum charging voltage. If the Absorption’ voltage for your battery type is too
high, please select another charging profile. Do not change the original settings
without confirming the battery manufacturer’s recommendations or consulting the
battery manufacturer.
Batt. Type
This screen shows and allows changes to the Battery Type & Battery
size setting:
Batt. Type The Battery type can selected from AGM, Standard & Calcium types.
AGM - is the low setting, with a maximum charge rate of 14.4 volts, AGM
batteries are a sealed deep cycle battery, similar to a Gel battery.
Standard - is the medium setting, with a maximum charge rate of 14.6
volts, Standard batteries are not sealed and have vents/caps to allow
maintenance of the water levels in the cells
Calcium - Is the High setting, with a maximum charge rate of 14.8 volts,
Calcium batteries can be sealed or vented, they are constructed of a
calcium/lead mix to improve its strength, heat and corrosion resistance,
generally used for marine or 4wd starting batteries.
Batt. Type
Batt. AH
100AH
AGM
7
Char.cur:
Rate.Vol:
20A
24V