Product Manual

3 MONITOR INFORMATION
Absorb. Rec.
This screen shows the Absorption Recover voltage setting and the
Low Voltage Reconnect setting:
Absorb. Rec. The voltage level that will re-trigger the charger back into the Absorption
stage of charge.
Low Volt. Rect. Not applicable.
Under Volt. Rect
This screen shows the Under Voltage Reconnect and Under Voltage
Warning voltage levels:
Under Volt. Rect The battery voltage level that will reconnect the solar panel to the battery
and resume charging after a previous low voltage disconnection
Under Volt. Warn The voltage level that will trigger the LED to turn yellow, warning you that
the battery voltage is low. At this point you should manage your loads and
disconnect or turn off non essential loads to save battery power.
Low Volt. Disc
This screen shows the Low Voltage Disconnect and Discharge
voltage limit for the battery:
Low Volt. Disc Not applicable.
Discharge Limit Not applicable.
Equalize Time
This screen shows the Equalize and Absorption charging stage time
limits:
Equalize Time The time duration for the equalization charging stage, this stage is required
for battery maintenance of permanent installations and will trigger every
28 days
Absorb time This is the Absorb charging stage time duration, this setting is defaulted to
180 minutes, and can be adjusted from 10 - 180 minutes.
Note: Redarc does not recommend changing this or any of the default settings.
Absorb. Rec.
Low Volt. Rect.
11.5V
13.2V
Under Volt. Rect
Under Volt. Warn
11.5V
11.8V
Low Volt. Disc
Discharge Limit
10.1V
10.5V
Equalize Time
Absorb Time
10min
---min
9