Product Manual

THE SOLAR REGULATOR
REGULATOR FUNCTION
CONNECTION
The regulator should be connected to the battery according to the diagram above. The connection order
is indicated by the numbers circled.
Incorrect connection of the battery can damage the regulator.
The Remote temperature sensor is optional and the regulator will still operate without it connected.
The Remote monitor is optional and the regulator will still operate without it connected.
INDICATION
1. LED flash (multiple flashes per second) Short circuit - check the Solar panel and the battery to
make sure that they are connected correctly.
2. LED flash (1 flash per second) Fully charged.
3. LED ON Charging.
4. LED flash (1 flash every 3 seconds) Battery connected, no charge current.
5. LED OFF No connection or Over voltage.
+
+
+
-
-
-
2 1 6 5 4 3
Temperature sensor
Battery 1 charge status
Battery 2 charge status
Set Button
MODE
Battery type
Charge Priority
Charge Frequency
Remote
temperature
sensor
(optional)
Remote
monitor
(optional)
1 2
LED Indication Chart
(on side of regulator)