User Manual
STANDARD WIRING DIAGRAMS
3
Loads
Load
Circuit
Breaker*
Fuse*
Auxiliary
Battery
Start
Battery
Fuse*
SBI
3
3
4
5
6
7
1
SBI with External LED
SBI with Push Button
for Start Assist
Momentary
Pushbutton
Momentary
Pushbutton
LED
Resistor values:
12V = 1kΩ or 24V = 2.2kΩ
SBI with Push Button
and LED
LED
NO RESISTOR REQUIRED.
Override
Wire
Override
Wire
Override
Wire
Override
Wire
OPTION 1 OPTION 2 OPTION 3
2
5A
Fuse
5A
Fuse
Override
Wire
(BLUE)
Ground
Wire
(BLACK)
Start
Terminal
Auxiliary
Terminal
• Ensure adequately sized cable
is used as per the chart on
page 1.
• Ensure the auxiliary battery
is properly grounded to a
common chassis earth point.
• Ensure the SBI ground wire is
making good contact with the
chassis ground point.
• When using fuses make sure
that the fuse makes a good low
resistance connection.
• Fuse/Circuit Breaker ratings
are dependent on the type of
installation and the size of the
loads, refer to chart on page 1.