User Manual

STANDARD WIRING DIAGRAMS
3
Loads
Load
Circuit
Breaker*
Fuse*
Auxiliary
Battery
Start
Battery
Fuse*
SBI
3
3
4
5
6
7
1
SBI with External LED
SBI with Push Button
for Start Assist
Momentary
Pushbutton
Momentary
Pushbutton
LED
Resistor values:
12V = 1kΩ or 24V = 2.2kΩ
SBI with Push Button
and LED
LED
NO RESISTOR REQUIRED.
Override
Wire
Override
Wire
Override
Wire
Override
Wire
OPTION 1 OPTION 2 OPTION 3
2
5A
Fuse
5A
Fuse
Override
Wire
(BLUE)
Ground
Wire
(BLACK)
Start
Terminal
Auxiliary
Terminal
Ensure adequately sized cable
is used as per the chart on
page 1.
Ensure the auxiliary battery
is properly grounded to a
common chassis earth point.
Ensure the SBI ground wire is
making good contact with the
chassis ground point.
When using fuses make sure
that the fuse makes a good low
resistance connection.
Fuse/Circuit Breaker ratings
are dependent on the type of
installation and the size of the
loads, refer to chart on page 1.