Operating instructions
4
FOR FREE TECHNICAL ASSISTANCE - Ph: (08) 8322 4848 Fax: (08) 8387 2889 Email: power@redarc.com.au
3.0 OPERATION
The SBC1205 has been designed to return a discharged battery to 100% charge through a rigorous charging
cycle. This charging cycle assumes that no load is connected to the battery during charging, otherwise full
charge may not be achieved. It is also possible that the charger may determine that the charging
characteristics with a load applied appears like a fault and terminate the charging cycle. Small loads such
as the loads drawn by vehicle electronics with the ignition turned off do not present a problem to normal
operation. The charging cycle consists of a number of stages as described over the page, and when
completed remains in a float mode indefinitely. It is safe to leave the battery connected to the charger as
the float mode will not allow over charging whilst maintaining the battery to a fully charged state.
If the battery remains connected to the charger and a charge cycle completes, the charging cycle will not
restart even if the battery becomes discharged by a load. Instead, the charger will continue in float mode.
The full charge cycle can only be restarted by turning the charger off, waiting for approximately 10
seconds, then turning it back on again.
4-STAGE CHARGING PROCESS
3.1 Indicators
There are three visual indicators to assist the operator during the charging process, and these are
described below.
Charging indicator (Orange)
This indicator is used during the first three stages of charging (Boost, Absorption and Equalise), and flashes at
different rates to indicate the charging mode.
Boost Mode: Orange indicator ON-single flash. This mode delivers the bulk charge to the battery by
delivering maximum constant current. This stage is time limited to cater for a fully discharged 40Ah battery,
however the time taken in this mode does greatly depend on the condition and state of charge of the
battery.
Absorption Mode: Orange indicator ON-double flash.
This mode must be finished before Equalise can take place. The charger maintains constant charging
voltage, while the current reduces. This voltage is close to the gassing voltage of the electrolyte.
Equalise Mode: Orange indicator ON – triple flash.
This mode brings the battery to full charge. A higher voltage is applied to induce some gassing, which mixes
the electrolyte, bringing the cells to equal potential. In a low maintenance battery, most of the hydrogen
and oxygen gasses will recombine and will not dry out the battery.
Note that this mode is not run for Gel/AGM batteries.
B O O S T A B S O R P T IO N E Q U A L IS E FL O A T
C H A R G IN G
TIM E
C H A R G E
C U R R EN T (A )
C H A R G E
VO L TA G E (V )
5
FOR FREE TECHNICAL ASSISTANCE - Ph: (08) 8322 4848 Fax: (08) 8387 2889 Email: power@redarc.com.au
Ready indicator (Green) Continuously ON
Indicates that the battery charging process is complete, and full charge (100%) has been achieved. The
charger is now in the maintenance mode (Float), where it will keep the battery at full charge indefinitely
without the fear of overcharging. The battery is ready for use, and can be disconnected.
Ready indicator (Green) Flashing
Indicates that the battery capacity has exceeded the maximum charge time allowable in one charge cycle.
The battery charging process has timed out, the charger is now in the maintenance mode (Float), where it will
keep the battery at its current level of charge indefinitely. The charger can now be turned off and back on
again to restart the charging cycle and hence achieve full charge.
4.0 TROUBLE SHOOTING
The Redarc SBC1205 is one of the most advanced chargers on the market. It has been designed to detect and
advise the operator of a variety of fault conditions, and will terminate the charging cycle immediately a fault is
detected. This ensures that the charger does not attempt to charge a faulty battery, which protects the
charger, battery and most importantly the user.
4.1 Fault Detection LED (Red)
When faults are detected, the charger shuts down the charging process and displays the nature of the
fault via a Red flashing LED. Possible faults are;
Continuously on-Hardware failure detected:
The SBC1205 failed its self-test on power up. The unit should be returned to the supplier for inspection.
One Flash-Over current detected:
An excessive current will cause this fault. This will indicate a faulty battery if it occurs during a charging
cycle, but not necessarily if it happens upon connection. This fault may also be triggered by trying to
charge a lower voltage battery than specified e.g. 6V on a 12V charger.
Two Flashes-Voltage problem detected:
A battery that remains at a low voltage for too long or a battery which has a higher voltage than specified, will
cause this fault e.g. attempting to charge a 24V battery on a 12V charger.
Three Flashes-Faulty battery detected:
Charging a battery with a dead cell will result in this fault. With some batteries it might take longer to detect the
fault than in others, depending upon the initial level of charge and also how damaged the battery is. If the
battery is badly damaged, the fault may show up as over current.
Four Flashes- Overheat:
The charger is too hot to operate, the charging process is suspended, and will recommence once the charger
has cooled down. This can happen on a very hot day, if the charger is positioned in a very hot place while
charging or if the ventilation holes have been blocked. Also, the fan may not be functioning properly.
4.2 Electrolyte (Not applicable for AGM/Gel battery types)
If the battery charger detects a fault it will shut down immediately. In this case, check if connections to the
battery are tight. Is the battery sound? Check the electrolyte levels and use a Hydrometer to check for “dead”
cells. A lead-acid battery is considered to be discharged when the specific gravity of the electrolyte is less than
1.16.
Fault