RS Series 12V & 24V Inverters (350W model)
RS SERIES INVERTERS (350W) REDARC Pure Sine Wave Inverters produce a pure sine wave output. This means that the power output from a REDARC Pure Sine Wave Inverter is not only the same as the mains supply, it’s often better! WARNINGS & SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS - This manual contains IMPORTANT SAFETY INSTRUCTIONS for the REDARC RS series 350W Pure Sine Wave Inverters.
WARNINGS AND SAFETY INSTRUCTIONS 5. 6. 7. 8. 9. 1. 2. 3. 4. 5. 6. 7. 8. Be extra cautious so as to reduce the risk of dropping a metal tool onto a vehicle battery. Doing so might cause the battery to spark or might short-circuit the battery or other electrical parts that may cause an explosion. Remove personal metal items such as rings, bracelets, necklaces, and watches when working with a battery.
CONTENTS Table of Contents Page Warnings and Safety Instructions Contents 1 Introduction 1. Quick Start Guide 2. Specifications 3. Dimensions 2 User Guide 1. Front Panel Operation 1. Main Switch 1. Function Switch 1. Output Voltage 2. Output Frequency 3. Power Saving 2. LED Indication 2. Rear Panel Operation 1. Remote Port(RJ11) 2. Remote Control Green Terminal 3. Chassis Ground 4. DC Input Connection 3. Protection Features 3 Installation 1. Mounting 2. Ventilation Fan 3.
1 INTRODUCTION 1.1 Quick Start Guide 1 Ensure no loads are connected to the Inverters AC Output. 2 Ensure that the Inverter Main Switch is set to the ‘OFF’ position. Ensure all Loads are Disconnected Set Main Switch to ‘OFF’ 4 5 Ensure that the cable is of adequate size and is protected by the correct sized fuse. Connect Chassis Ground Terminal to Negative Input Terminal 3 Connect the DC cables to the Inverters DC Input Terminals.
1 INTRODUCTION 1.2 Specifications R-12-350RS Output Voltage Rated Power Max. Rated Input Current R-24-350RS 200 / 220 / 230 / 240VAC ± 5% 350W 44A 22A Surge Power 700W Waveform Pure Sine Wave (THD<3% @ VCD, linear load) Frequency 50/60Hz ± 0.1% Nominal Input Voltage 12VDC 24VDC 10.0~15.5VDC 20.0~31.0VDC 89% 90% Power Saving mode <90mA <60mA No load standby <0.9A <0.5A 10V ± 0.25V 20V ± 0.5V Battery Low Alarm 10.5V ± 0.25V 21V ± 0.5V Battery Low Restart 12V ± 0.25V 24V ± 0.
127 [5.00] 150 [5.91] 6 187 [7.36] Dimensions 116.0 [4.57] 1.3 35.7 [1.41] INTRODUCTION 68 [2.68] 22 [0.
2 USER GUIDE RISK OF ELECTRICAL SHOCK. DO NOT DISASSEMBLE THE INVERTER - THE INTERNAL CIRCUITRY CONTAINS HAZARDOUS VOLTAGES. ATTEMPTING TO SERVICE THE UNIT YOURSELF MAY RESULT IN ELECTRIC SHOCK OR FIRE AND WILL VOID THE UNIT WARRANTY. 2.1 Front Panel Operation The R-12-350RS and R-24-350RS are members of the most advanced line of mobile AC power systems available. To get the most out of the power inverter, it must be installed and used properly.
2 USER GUIDE 2.1.3 Indicator LED Status LED Signal Power On/Normal Saving Mode (Shutdown after 30 mins) Green Green Green Output over load (100-115%) Red (Shutdown after 30 seconds and restart 4 times) Output Short Circuit Red (Shutdown after 2 seconds and restart 4 times) Over Temperature Shutdown High Battery High Battery Red Red Red Red Red Red Red Red Red Red Orange Orange Orange Orange Orange Orange Low Battery (5 short beeps every 15 sec) Shutdown Low Battery 2.
2 USER GUIDE 2.2.1 Remote Port (RJ-11) A The RS Series inverter can be used with the REMOTE-RS remote controls. To enable use, the main switch on the inverter must be set to the “REMOTE” position. Pin Number 1 2 3 4 5 6 Signal Description (1) Reserved GND Reserved Reserved RMT Reserved 2.2.
2 USER GUIDE 2.2.4 DC Input Connection D Prior to installation: • DC Supply cables should be as short as possible (no longer than the values in table 2.2.4.1) • The size of the cable should be thick enough to maintain a voltage drop of less than 2% when carrying the maximum input current. This will help prevent frequent low-input voltage warnings and shutdown. • The following sizes of cables and fuses are recommended for connection of the supply batteries to inverter, see table 2.2.4.
3 INSTALLATION 3.1 Mounting The power inverter should be used in an environment that meets the following requirements: 1. Dry – Do not allow water to drip on or enter into the inverter. 2. Cool – Ambient air temperature should be between 0°C and 40°C, the cooler the better. 3. Safe – Do not install the inverter in a battery compartment or other areas where volatile fumes may exist, such as fuel storage areas or engine compartments. 4.
3 INSTALLATION 3.3 DC wiring connections RISK OF ELECTRICAL SHOCK. BEFORE PROCEEDING, CAREFULLY CHECK THAT THE INVERTER IS NOT CONNECTED TO ANY BATTERIES AND THAT ALL WIRING IS DISCONNECTED FROM ANY ELECTRICAL SOURCES. DO NOT CONNECT THE OUTPUT TERMINALS OF THE INVERTER TO AN INCOMING AC SOURCE. DC supply cables should be kept as short as possible whilst still adhering to the above installation requirements (ideally less than 1.8m / 6ft).
3 INSTALLATION Ensure that all the DC connections are tight - torque to 2.8 Nm (1.5 ft-lbs). Loose connections could result in overheating and can be a potential hazard. M5 Screw Cable Ring Terminal Do not operate the inverter with damaged or substandard wiring. Selecting the wrong cable or fuse size could result in harm to the installer or user and/or damage to the inverter or other appliances installed in the system.
4 TWO YEAR PRODUCT WARRANTY Over the last three decades our company has established a reputation as the power conversion specialist. A 100% Australian-owned company, we have met the needs of customers in transport and other industries through exciting, innovative thinking.
Free technical assistance! please contact REDARC Electronics 23 Brodie Road North, Lonsdale SA (08) 8322 4848 power@redarc.com.au www.redarc.com.au Copyright © 2017 REDARC Electronics Pty Ltd. All rights reserved. MADE IN CHINA www.redarc.com.