User Manual
SPECIFICATIONS
CE25 CE40
Input Voltage Range 20V-32V 20V-32V
Output Voltage Range 6V-16V 6V-16V
No Load Current <100mA <100mA
Standby Current <10mA <10mA
Input Fuse Rating (24V) 40A (Not supplied) 50A (Not supplied)
Output Fuse Rating 40A (Not supplied) 50A (Not supplied)
Output Current (Max.) 25A 40A
Operating Temperature -20°C to +80°C -20°C to +80°C
Minimum O/P Battery Volts 6V 6V
Weight 680g
Dimensions 150x120x37mm
Warranty 2 years
Standards CE, C-Tick, AS/NZS CISPR11:2004
WIRING
For maximum effi ciency the Charge Equaliser must be fi tted as close as practical to the lower
battery. Fuses or circuit breakers (not provided) MUST be fi tted to the input and output wires as
outlined in the diagram and as per the precautions below. The fuses are essential to ensure the
safety of the vehicle’s wiring in the event of a short circuit. Avoid direct steam/pressure cleaning
of the unit as the chemicals used in the fl uids can be corrosive.
2
Input
Fuse
24V
Battery
Bank
Chassis
Earth
Not
supplied
To 24V
System
Output
Fuse
Not
supplied
Equipment
Fuse
Not
supplied
CE
Red
Black
Brown